Hearth and Home Technologies NDV4842L, NDV4236IL Vent Information and Diagrams, A. Approved Pipe

Models: NDV3933IL NDV3036IL NDV4236L NDV4842L NDV4236I NDV3933L NDV4236IL NDV4842 NDV3630L NDV3933I NDV4842IL NDV4236 NDV4842I NDV3630 NDV3933 NDV3630I

1 84
Download 84 pages 46.5 Kb
Page 23
Image 23
7 Vent Information and Diagrams

7 Vent Information and Diagrams

A. Approved Pipe

This appliance is approved for use with Hearth & Home

ÎTechnologies DVP and SLP venting systems. Refer to Sec- tion 16B for vent component information.

DO NOT mix pipe, fittings or joining methods from different manufacturers.

The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall.

WARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance.

D. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

Pipe measurements are shown using the effective length of pipe (see Figure 7.2).

Measurements are made from the appliance outer wrap, not from the standoffs.

Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 6.5).

Vertical terminations are measured to bottom of termination cap.

Horizontal pipe installed level with no rise.

B. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

 

 

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Subsequent sections of horizontal length

 

 

C. Use of Elbows

Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 7.1).

Two 45º elbows may be used in place of one 90º elbow. On 45º runs, one foot of diagonal is equal to 8-1/2 (216 mm) inches horizontal run and 8-1/2 (216 mm) inches vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 7.1).

Vertical in.1/2 -8

8-1/2 in.

A. Approved Pipe Horizontal D. Measuring Standards

Figure 7.1

 

 

 

 

 

 

 

 

 

Effective Height/Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe

 

inches

 

mm

 

 

 

 

 

 

 

 

 

DVP4

 

4

 

102

 

 

 

 

 

 

 

 

 

DVP6

 

6

 

152

 

 

 

 

 

 

 

 

 

 

 

 

Effective

 

 

 

 

 

DVP12

 

12

 

305

 

 

Height/Length

 

 

 

 

 

 

DVP24

 

24

 

610

 

 

 

 

 

 

 

 

 

DVP36

 

36

 

914

 

 

 

 

 

 

 

 

 

DVP48

 

48

 

1219

 

 

 

 

 

 

 

 

 

DVP6A

 

3 - 6

 

76 - 152

 

 

 

 

 

 

 

 

 

DVP12A

 

3 - 12

 

76 - 305

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DVP12MI

 

3 - 12

 

76 - 305

DVP Pipe

 

DVP24MI

 

3 - 24

 

76 - 610

 

 

 

 

 

 

(see chart)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Effective Height/Length

 

 

 

 

 

 

 

 

 

Pipe

 

inches

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLP4

4

102

 

 

Effective

 

 

 

 

 

 

SLP6

6

152

 

Height/Length

 

 

 

 

 

SLP12

12

305

 

 

 

 

 

 

 

 

 

SLP24

24

610

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLP36

36

914

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLP48

48

1219

SLP Pipe

 

SLP6A

2 - 6

51 - 152

 

SLP12A

2 - 12

51 - 305

(see chart)

 

 

 

 

 

 

 

ÎFigure 7.2 Pipe Effective Length

Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08

23

Page 23
Image 23
Hearth and Home Technologies NDV4842L, NDV4236IL Vent Information and Diagrams, A. Approved Pipe, D. Measuring Standards