Installing Flue Components

Installing Flue Components

After determining which set of starting collars will be used (top or rear), follow flueing instructions accordingly.

Flueing Out the Rear Flue

Remove the rear collar seal cap by cutting the strap at each end (see Figure 17).

Next, remove the insulation from the rear flue, pull the heat shield out from outside of the heater.

! WARNING: THE TOP FLUE COLLAR SEAL CAP MUST REMAIN ATTACHED TO THE TOP FLUE COLLAR IF THE FLUE

SYSTEM IS ATTACHED TO THE REAR STARTING COLLARS. SEE FIGURE 17.

Flueing Out the Top Flue

Remove the top collar cover plate. Remove the seal cap and both pieces of insulation in the top collars (see Figure 17). Remove the heat shield inside the top collars from the outside of the heater.

!WARNING: THE REAR FLUE COL- LAR SEAL CAP MUST REMAIN AT- TACHED TO THE REAR FLUE COL- LARS IF THE FLUE SYSTEM IS AT- TACHED TO THE TOP STARTING COLLARS. SEE FIGURE 17.

!WARNING: FAILURE TO REMOVE INSULATION IN THE SET OF COL- LARS YOU ARE USING COULD CAUSE A FIRE.

!WARNING: YOU MUST LEAVE THE INSULATION IN PLACE IN THE SET OF COLLARS YOU ARE NOT USING.

Insert screwdriver

FLUEING OUT REAR

 

FLUEING OUT TOP

 

 

 

or similar object

 

SEAL

 

here to remove cap.

SEAL

INSULATION,

 

CAP

 

CAP

DISCARD

 

 

 

BOTH

 

 

 

PIECES and

 

 

 

HEAT SHIELD

HEAT

SHIELD

HEAT

DISCARDSHIELD

INSULATION

and

HEAT SHIELD

CUT

HERE

Figure 17.

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

17

Page 17
Image 17
Hearth and Home Technologies SL-550TRSI-AUE manual Installing Flue Components, Flueing Out the Rear Flue