Electronic Ignition System - (continued)

Symptom

Possible Causes

Corrective Actions

10. Glass soots.

a. Flame impingement on

Adjust the log set so that the flame does not impinge on it.

 

logs.

 

 

b. Improper venturi setting. Adjust the air shutter at the base of the burner.

 

c. Debris around venturi.

Inspect the opening at the base of the burner. It is imperative that NO

 

 

material be placed in this opening.

11. Flame burns blue

a. Insufficient oxygen

1. Check to make sure flue cap is installed properly and free of debris.

and lifts off burner.

being supplied.

Make sure that flue system points are tight and have no leaks.

 

 

2. Check to make sure that no material has been placed in the opening at

 

 

the burner base or in the area of the air holes in the center of the base

 

 

pan beneath the burne.

 

 

3. Be sure glass is tighened properly on unit, particularly on top corners.

36

Heat & Glo • SL-550TRSI-AUE2079-902 Rev. B • 7/06

Page 36
Image 36
Hearth and Home Technologies SL-550TRSI-AUE manual Pan beneath the burne