V=VENT TERMINAL

25

 

 

v

G

 

 

 

 

 

 

 

D

 

A

H

 

 

 

 

 

 

 

E

 

 

 

 

 

v

 

 

 

 

 

L

C

openable

fixed closed

 

 

v B

 

 

v

 

 

 

 

 

v

 

 

 

 

 

 

 

 

 

F v

v

B

M

 

 

I

 

 

B

B

v

X

 

 

 

 

 

J or K

 

 

 

 

 

A

V=VENT TERMINAL

X =AIR SUPPLY INLET 2=AREA WHERE TERMINAL IS NOT PERMITTED

A= 12"clearances above grade, veranda, porch, deck or balcony

B= 12"clearances to window or door that may be opened

C

= 9" (U.S.A.)

clearance to permanently closed window

 

12" (Canada)

 

D= 18"vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the center-line of the terminal

E= 18"clearance to unventilated soffit

F

=

9"

clearance to outside corner

G

=

6"

clearance to inside corner

H

=

3 ft. (Canada)

not to be installed above a gas meter/regulator assembly

 

 

 

within 3 feet (90 cm) horizontally from the center-line of

 

 

 

the regulator

I

=

3 ft. (U.S.A.)

clearance to service regulator vent outlet

 

 

6 ft. (Canada)

 

J

=

9" (U.S.A.)

clearance to non-mechanical air supply inlet to building

 

 

12" (Canada)

or the combustion air inlet to any other appliance

K

=

3 ft. (U.S.A.)

clearance to a mechanical air supply inlet

 

 

6 ft. (Canada)

 

*L

=

7 ft.

clearance above paved sidewalk or a paved driveway

 

 

 

located on public property

**M

=

18"

clearance under veranda, porch, deck or balcony

*a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

**only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor.

NOTE: Local Codes or Regulations may require different clearances.

Figure 25. Vent Termination Minimum Clearances

CAUTION

IF EXTERIOR WALLS ARE FINISHED WITH

 

VINYL SIDING, IT IS NECESSARY TO INSTALL

 

THE VINYL PROTECTOR KIT TO THE TOP OF

 

THE EXTERIOR FIRESTOP (FOR ALL ROUND

 

TERMINATION CAPS).

Page 28
Image 28
Heat & Glo LifeStyle 6000 XLT, 8000 DVTFL If Exterior Walls Are Finished With, Vinyl Siding, It Is Necessary To Install