Model 6000XLT & 8000DVTFL

Model 6000XLT & 8000DVTFL

VENTING WITH ONE (1) 90° ELBOW

 

V (FT.)

H (FT.) (8000 & 6000’s)

H (FT.) SL-42DVT

1' MIN. (305 mm)

6' MAX. (1.86 m)

3’ MAX. (914mm)

2' MIN. (610 mm)

12' MAX. (3.66 m)

6’ MAX. (1.83m)

3' MIN. (914 mm)

18' MAX. (5.58 m)

9’ MAX. (2.74m)

4' MIN. (1.22 m)

24' MAX. (8.44 m)

12’ MAX. (3.66m)

20' MAX. (6.2 m)

24' MAX. (8.44 m)

12’ MAX. (3.66m)

 

(21' IN CANADA 6.3 m)

 

FOR SL-42DVT

 

 

NOTE: IF A 90° ELBOW IS FIRST

 

ATTACHED TO THE UNIT, THE

 

MAXIMUM HORIZONTAL RUN H IS

V

2-FEET (610 MM).

 

 

H

 

 

NOTE: MODEL 6000 ARCH

A 12-INCH LENGTH OF STRAIGHT VENT PIPE MUST BE THE FIRST

VENT COMPONENT ATTACHED TO THE UNIT.

FOR 8000DVTFL, 6000DVTFL, 6000XLT

NOTE: IF A 90° ELBOW IS FIRST ATTACHED TO THE UNIT, THE MAXIMUM HORIZONTAL RUN H IS 3-FEET (914 MM).

H

V

Figure 10. Venting with One 90° Elbow

NOTE: For corner installations: A 6-inch (152mm) MINIMUM length of straight pipe must be first attached to the fireplace before 90O eblow. This will allow the vent pipe to clear the top standoffs.

12

Page 15
Image 15
Heat & Glo LifeStyle 8000 DVTFL manual Model 6000XLT & 8000DVTFL, FOR SL-42DVT, NOTE: IF A 90 ELBOW IS FIRST, FEET610 MM