Model 6000XLT & 8000DVTFL
VENTING WITH ONE (1) 90° ELBOW |
| |
V (FT.) | H (FT.) (8000 & 6000’s) | H (FT.) |
1' MIN. (305 mm) | 6' MAX. (1.86 m) | 3’ MAX. (914mm) |
2' MIN. (610 mm) | 12' MAX. (3.66 m) | 6’ MAX. (1.83m) |
3' MIN. (914 mm) | 18' MAX. (5.58 m) | 9’ MAX. (2.74m) |
4' MIN. (1.22 m) | 24' MAX. (8.44 m) | 12’ MAX. (3.66m) |
20' MAX. (6.2 m) | 24' MAX. (8.44 m) | 12’ MAX. (3.66m) |
| (21' IN CANADA 6.3 m) |
|
FOR |
|
|
NOTE: IF A 90° ELBOW IS FIRST |
| |
ATTACHED TO THE UNIT, THE |
| |
MAXIMUM HORIZONTAL RUN H IS | V | |
|
| |
| H | |
|
|
NOTE: MODEL 6000 ARCH
A
VENT COMPONENT ATTACHED TO THE UNIT.
FOR 8000DVTFL, 6000DVTFL, 6000XLT
NOTE: IF A 90° ELBOW IS FIRST ATTACHED TO THE UNIT, THE MAXIMUM HORIZONTAL RUN H IS
H
V
Figure 10. Venting with One 90° Elbow
NOTE: For corner installations: A
12