MAJOR U.S. BUILDING CODES

For Vertical Terminations - To locate the vent and install the vent sections:

• Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.

• Make the outline of the roof hole around the centerpoint nail.

• The size of the roof hole framing dimensions depend on the pitch of the roof. There MUST BE a 1-inch (25.4 mm) clearance from the vertical vent pipe to combustible materials.

• Mark the roof hole accordingly.

• Cover the opening of the installed vent pipes.

• Cut and frame the roof hole.

• Use framing lumber the same size as the roof rafters and install the frame securely. Flashing anchored to the frame must withstand heavy winds.

• Continue to install concentric vent sections up through the roof hole (for inside vent installations) or up past the roof line until you reach the appropriate distance above the roof (for outside terminations).

 

WARNING

 

MAJOR U.S. BUILDING CODES

 

SPECIFY MINIMUM CHIMNEY AND/OR

 

VENT HEIGHT ABOVE THE ROOF TOP.

 

THESE MINIMUM HEIGHTS ARE

 

NECESSARY IN THE INTEREST OF

 

SAFETY. SEE THE FOLLOWING

 

DIAGRAM FOR MINIMUM HEIGHTS,

 

PROVIDED THE TERMINATION CAP IS

 

AT LEAST EIGHT (2) FEET FROM A

 

VERTICAL WALL AND 2-FEET BELOW

 

A HORIZONTAL OVERHANG.

NOTE

 

This also pertains to vertical vent systems installed

 

on the outside of the building.