Heat Controller VMH12SC-1 Indoor Unit Error Display, Diagnosis and Solution, VMH Series

Models: VMH18SC-1 VMH09SC-1 VMH24SC-1 VMH12SC-1

1 45
Download 45 pages 50.02 Kb
Page 36
Image 36
9.1 Indoor Unit Error Display

Service Manual

VMH Series

Heat Controller, Inc.

 

 

 

9.1 Indoor Unit Error Display

Display

LED STATUS

 

 

 

E0

EEPROM parameter error

 

 

 

E1

Indoor / outdoor units communication protection

 

 

 

E2

Zero-crossing signal error

 

 

 

E3

Indoor fan speed out of control

 

 

 

E5

Open or short circuit of outdoor temperature sensor

 

 

 

E6

Open or short circuit of room or evaporator temperature sensor

 

 

 

E7

Outdoor fan speed out of control

 

 

 

P0

IBM malfunction or IGBT over-strong current protection

 

 

 

P1

Over voltage or too low voltage protection

 

 

 

P2

Temperature protection of compressor top.

 

 

 

P3

1 outdoor temp below 5°F(-15°C)

 

 

 

P4

Inverter compressor drive error

 

 

 

Note: E4 & P3: Reserved function

9.2 Diagnosis and Solution

EO:

9.2.1 EEPROM parameter error diagnosis and solution

Shut off the power supply and turn it on 5s later

Does EO code clear

Is the EEPROM chip plugged in indoor PCB well?

No

Correct the connection

Replace the main PCB of indoor unit