Heatiator GB4336 Symptom, Possible Causes, Corrective Actions, Pilot sparks, but pilot will

Models: GB4336

1 52
Download 52 pages 25.36 Kb
Page 36
Image 36

 

Symptom

 

Possible Causes

Corrective Actions

4.

Pilot sparks, but pilot will

A.

Correct gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet pressure

 

not light.

 

 

reading is within acceptable limits, inlet pressure must not exceed 14 in. w.c.

 

 

B.

Ignitor gap is too large.

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in.

 

 

 

 

 

 

 

C.

Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

D.

Module voltage output/

Replace module.

 

 

 

valve/pilot solenoid ohms

 

 

 

 

readings.

 

36