14 Troubleshooting

14 Troubleshooting

With proper installation, operation and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualifi ed service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualifi ed service technician.

A. Standing Pilot Ignition System

 

Symptom

 

Possible Causes

Corrective Actions

1.

After repeated triggering

A.

Defective ignitor.

Check the spark at the electrode and pilot. If there is no spark and the

 

of the red or black piezo

 

 

electrode wire is properly connected, replace the ignitor.

 

ignitor button, the spark

 

 

 

 

B.

Defective pilot or

Using a match, light the pilot. If the pilot lights, turn off the pilot and trigger

 

ignitor will not light the

 

 

misaligned electrode

the red piezo ignitor button again. If the pilot lights, an improper gas/air

 

pilot.

 

 

 

(spark at electrode).

mixture caused the bad lighting and a longer purge period is recommended.

 

 

 

 

 

 

 

If the pilot will not light, ensure the gap at the electrode and pilot is 1/8 in. to

 

 

 

 

have a strong spark. If the gap is OK, replace the pilot.

 

 

C.

No gas or low gas

Check the remote shut-off valves from the appliance. There is usually a

 

 

 

pressure.

valve near the gas main. There can be more than one valve between the

 

 

 

 

appliance and the main.

 

 

D.

No LP in tank.

Check the LP (propane) tank. You may be out of fuel.

2.

The pilot will not stay lit

A.

Defective thermocouple.

Check that the pilot fl ame impinges on the thermocouple. Clean and/or

 

after carefully following

 

 

adjust the pilot for maximum fl ame impingement.

 

the lighting instructions

 

 

Ensure that the thermocouple connection at the gas valve is fully inserted

 

 

 

 

 

 

 

 

and tight (hand tighten plus 1/4 turn).

 

 

 

 

Disconnect the thermocouple from the valve, place one millivolt meter lead

 

 

 

 

wire on the tip of the thermocouple and the other meter lead wire on the

 

 

 

 

thermocouple copper lead. Start the pilot and hold the valve knob in. If the

 

 

 

 

millivolt reading is less than 15mV, replace the thermocouple.

 

 

B.

Defective valve.

If the thermocouple is producing more than 15 millivolts, replace faulty valve.

3.

The pilot is burning, there

A.

ON/OFF switch or wires

Check the ON/OFF switch and wires for proper connections. Place the

 

is no gas burning, the

 

are defective.

jumper wires across the terminals at the switch. If the burner comes on,

 

valve knob is in the ON

 

 

replace the defective switch. If the switch is OK, place the jumper wires

 

position, and the ON/

 

 

across the switch wires at the gas valve. If the burner comes on, the wires

 

OFF switch is in the ON

 

 

are faulty or connections are bad.

 

position.

B.

Thermopile may not be

If the pilot fl ame is not close enough physically to the thermopile, adjust the

 

 

 

 

 

generating suffi cient

pilot fl ame.

 

 

 

millivoltage.

Be sure the wire connections from the thermopile at the gas valve terminals

 

 

 

 

are tight and that the thermopile is fully inserted into the pilot bracket.

 

 

 

 

Check the thermopile with a millivolt meter. Take the reading at TH-TP&TP

 

 

 

 

terminals of the gas valve. The meter should read 325 millivolts minimum

 

 

 

 

while holding the valve knob depressed in the pilot position, with the pilot lit,

 

 

 

 

and the ON/OFF switch in the OFF position. Replace the faulty thermopile of

 

 

 

 

the reading is below the specifi ed minimum.

 

 

 

 

With the pilot in the ON position, disconnect the thermopile leads from

 

 

 

 

the valve. Take a reading at the thermopile leads. The reading should be

 

 

 

 

325 millivolts minimum. Replace the thermopile if the reading is below the

 

 

 

 

minimum.

 

 

C.

Defective valve.

Turn the valve knob to the ON position. Place the ON/OFF switch in the ON

 

 

 

 

position. Check the millivolt meter at the thermopile terminals. The millivolt

 

 

 

 

meter should read greater than 125mV. If the reading is acceptable, and if

 

 

 

 

the burner does not come on, replace the gas valve.

 

 

D.

Plugged burner orifi ce.

Check the burner orifi ce for stoppage. Remove stoppage.

 

 

E.

Wall switch or wires are

Follow the corrective action in Symptom and Possible Cause 1.A. above.

 

 

 

defective.

Check the switch and wiring. Replace where defective.

Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06

33