1Listing and Code Approvals

1Listing and Code Approvals

A. Appliance Certification

MODELS: GB4336/GB4942 Series

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: B-Vent Gas Appliance

STANDARD: ANSI Z21.50-2000/CSA 2.33-2000, IR41,

P4 and IR55

This product is listed to ANSI standards for “Vented Gas Fireplaces” and “Gas Fired Appliances for Use at High Al- titudes”.

This model (natural gas and propane) can be installed in a bedroom (in the United States) which has a total volume of unconfi ned space appropriate to the particular installation. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA54 (current edition), The Uniform Mechanical Code - (cur- rent edition), and local building offi cials for the options al- lowed in obtaining an effective bedroom volume of uncon- fi ned space.

This model (natural gas and propane) can be installed in a bedroom (in Canada) if a thermostat is installed with the ap- pliance. Consult local code authorities.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

C. BTU Specifications

Geneva

4336 Series

4942 Series

Input Rate (NG)

34,000 BTU/hr.

36,000 BTU/hr.

 

 

 

Input Rate (LP)

34,000 BTU/hr.

36,000 BTU/hr.

Orifi ce Size (LP)

#52

#51

 

 

 

Orifi ce Size (NG)

#35

#32

D. High Altitude Installations

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang- ing the existing burner orifi ce to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop- er orifi ce size, check with the local gas utility.

If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.

B. Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defi ned by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certifi ed to the requirements of ANSI Z97.1 and

CPSC 16 CFR 1202 (Safety Glazing Certifi cation Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Section 1201.5 “Certifi cation and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certifi cate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

Note: Glass doors are not optional in the Commonwealth of Massachusetts. They are required.

A. Appliance Certification WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

E. Non-Combustible Materials

Materials that are reported as passing ASTM E 136, Stan- dard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750° C, shall be considered non-combus- tible materials.

F. Combustible Materials

Materials made of or surfaced with wood, compressed pa- per, plant fi bers, plastics, or other material that can ignite and burn, whether fl ame proofed or not, or whether plastered or unplastered shall be considered combustible materials.

4

Heatilator • GB4336/GB4992 • 4003-085 Rev H • 04/06

Page 4
Image 4
Heatiator GB4336 1Listing and Code Approvals, A. Appliance Certification, C. BTU Specifications, B. Glass Specifications