Heatiator HEIR42T Framing and Clearances, A. Selecting Appliance Location, A D B C B E, E F B

Models: HEIR50H HEIR36T HEIR36H HEIR50T HEIR42T HEIR42H

1 79
Download 79 pages 1.16 Kb
Page 19
Image 19
5 Framing and Clearances

5 Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

D

A

A

A. Selecting Appliance Location D AE

Manual backgroundB

C

B Manual backgroundManual background

Manual background E Manual background

Note: Dimensions below refer to a framed wall on which 1/2 inch wall sheathing has not been installed.

E

Manual backgroundF Manual background

B

F

 

 

 

A

B

C

D

E

F

 

 

HEIR36

Inches

74-1/4

59-1/2

105

26-1/2

23-1/2

29-3/4

 

 

 

Millimeters

1886

1511

2667

673

597

756

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIR42

Inches

78-9/16

65-9/16

111-1/16

28-5/8

23-1/2

32-13/16

 

 

 

Millimeters

1995

1665

2821

727

597

833

 

 

 

 

 

 

 

HEIR50

Inches

84-1/4

73-9/16

119-1/8

31-1/2

23-1/2

36-13/16

 

 

 

 

 

 

 

 

 

 

 

 

 

Millimeters

2140

1868

3026

800

597

935

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5.1 Appliance Locations

 

 

 

 

 

 

 

 

 

 

 