Heatiator HEIR50H, HEIR42H, HEIR42T, HEIR50T, HEIR36H, HEIR36T owner manual E. Hearth Extension, Model

Models: HEIR50H HEIR36T HEIR36H HEIR50T HEIR42T HEIR42H

1 79
Download 79 pages 1.16 Kb
Page 23
Image 23
E. Hearth Extension

E. Hearth Extension

WARNING! Risk of Fire! Non-combustible hearth exten- sion may be required when appliance is installed on com- bustible surface.

• Hearth extension must be non-combustible and serves to protect combustible floors in front of appli- ance. See Figure 5.11.

• The base of the fireplace may sit on a combustible sur- face. See Figure 5.11. The area in front of the appli- ance must be protected by a non-combustible hearth extension, unless the appliance is raised a minimum of three inches above the combustible floor or hearth. See Figure 5.11 and Figure 5.12.

AMODEL

B

MODEL

A

 

B

 

 

in.

 

mm

in.

 

mm

HEIR36

12

 

305

57-1/4

 

1454

HEIR42

12

 

305

63-5/16

 

1608

HEIR50

12

 

305

71-5/16

 

1811

Figure 5.10 Non-Combustible Hearth Extension Dimensions

NOTICE: DO NOT install a hearth that is greater than one inch thick. Hearth will interfere with installation of glass assembly. Total hearth height must not exceed one inch from bottom of appliance when appliance is installed directly on floor (including mortar, backer material, etc.)

If a hearth greater than one inch in thickness is desired, the appliance must be raised by the equivalent height to ensure that the hearth does not interfere with the installation of the glass assembly required for fireplace operation. See Figure 5.11.

NON-COMBUSTIBLE

BOARD

HEARTH CLEARANCE

BRACKET

NON-COMBUSTIBLE HEARTH EXTENSION 1 IN. THICK MAX.

WOOD OR OTHER COMBUSTIBLE

FLOOR OR PLATFORM

Figure 5.11 Appliance Installed on Combustible Surface

Non-Combustible Hearth Extension REQUIRED.

 

NON-COMBUSTIBLE

 

BOARD

 

HEARTH CLEARANCE

 

BRACKET

 

 

1/2 IN. MAX.

 

4 IN.

THICKNESS

 

COMBUSTIBLE

3 IN. MIN.

 

BUILDING

 

BOTTOM OF

 

MATERIAL

 

 

FIREPLACE

WOOD OR OTHER COMBUSTIBLE

 

FLOOR OR PLATFORM

 

Figure 5.12 Appliance Raised a Minimum of 3 Inches Above

Combustible Surface.

 

Non-Combustible Hearth Extension NOT REQUIRED.

 

Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12

23

Page 23
Image 23
Heatiator HEIR50H, HEIR42H, HEIR42T, HEIR50T, HEIR36H, HEIR36T owner manual E. Hearth Extension, Model