Heatiator HEIR50T Top Vent - Vertical Termination - continued, Three Elbows, V2 H1, Ht Max

Models: HEIR50H HEIR36T HEIR36H HEIR50T HEIR42T HEIR42H

1 79
Download 79 pages 1.16 Kb
Page 32
Image 32
V2

2. Top Vent - Vertical Termination - (continued)

Three Elbows

Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows.

V2

H1

WARNING! Risk of Fire!

HEIR36(NG/LP), HEIR42(NG/LP) and HEIR50(NG/LP) models require a minimum of 24 inches of vertical venting before attaching any elbow to the appliance.

DO NOT attach elbow directly to the appliance.

HEIR36 (NG/LP), HEIR42 (NG/LP), HEIR50 (NG/LP)

 

V1

H1

H2

V2

 

Ht Max.

2 ft

610 mm

*

*

**

7 in

 

178 mm

 

 

 

 

 

 

 

 

3 ft

914 mm

*

*

**

2 ft

 

610 mm

4 ft

1.2 m

*

*

**

4 ft

 

1.2 m

5 ft

1.5 m

*

*

**

8 ft

 

2.4 m

 

 

 

 

 

 

 

 

6 ft

1.8 m

*

*

**

12 ft

 

3.7 m

 

 

 

 

 

 

 

 

7 ft

2.1 m

*

*

**

14 ft

 

4.3 m

10 ft

3.0 m

*

*

**

20 ft

 

6.1 m

*H1 and H2 has no specific restrictions EXCEPT,

after V1 = 6 ft, then Ht Max = 2 x V1 **VT + HT = 60 ft Max.

H2

INSTALLED

HORIZONTALLY

V1

Figure 7.9

32

Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12

Page 32
Image 32
Heatiator HEIR50T, HEIR42H Top Vent - Vertical Termination - continued, Three Elbows, V2 H1, WARNING! Risk of Fire, Ht Max