2. Top Vent - Vertical Termination - (continued)

2. Top Vent - Vertical Termination - (continued)

2 ELBOWS

Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows.

V2

WARNING! Risk of Fire!

HEIR36(NG/LP), HEIR42(NG/LP) and HEIR50(NG/LP) models require a minimum of 24 inches of vertical venting before attaching any elbow to the appliance.

DO NOT attach elbow directly to the appliance.

HEIR36 (NG/LP), HEIR42 (NG/LP), HEIR50 (NG/LP)

 

V1

 

H1

V2

2 ft

 

610 mm

1 ft

305 mm

*

3 ft

 

914 mm

3 ft

914 mm

*

4 ft

 

1.2 m

4 ft

1.2 m

*

 

 

 

 

 

 

5 ft

 

1.5 m

9 ft

2.7 m

*

 

 

 

 

 

 

6 ft

 

1.8 m

12 ft

3.7 m

*

V1 + V2 + H1 = 50 ft (15.2 m) Max.

*No specific restrictions on this value EXCEPT V1 + V2 + H1 cannot exceed 60 ft (18.3 m).

After V1 = 6 ft, then H1 Max.= V1 x 2

H1

V1

Figure 7.8