CHAPTER 16
Content Management Application (CMA)
208 DL.3 Digital Light User Manual
DL.3 and DL.2 Media Server Configuration Options
DL.3 and DL.2 fixtures include configuration options for the internal projector, the lamp, the
menu display and motion features. The four tabs are labeled Server, Fixture, Lamp, and
Test /Res et.

Server Tab

DMX Settings

Fixture Info

Versio n Inf o

Misc

Configuration Item Configuration Value Options
DMX Start Channel 1-512
DMX Source DMX512 or Art-Net
Art-Net Subnet 0-16
Art-Net Universe 0-16
DMX Protocol Standard protocol designates a DMX channel range of 170
Dual protocol designates a DMX channel range of 132
Single protocol designates a DMX channel range of 94
Configuration Item Configuration Value Options
Model Read only
Fixture ID 1-255
Fixture Name Allows fixture name of up to 26 characters
IP Address Read only assigned to that unit by the router or Auto IP
Unique Number Read only assigned by factory
Disk Free Space Read only
Configuration Item Configuration Value Options
Software Read only
XPe Read only
Firmware Read only
Configuration Item Configuration Value Options
Ext S-Video Format
NTSC_M NTSC_MJ PAL_B PAL_D PAL_G
PAL_H PAL_I PAL_M PAL_N SECAM_B
SECAM_D SECAM_G SECAM_H SECAM_K SECAM_K1
SECAM_L SECAM_L1
Fixture Defaults On restores fixture defaults
Off displays whenever defaults has been changed
Reboot Server Check Reboot to restart the internal graphics engine