Hitachi HTS543212L9SA00 manual 14.40 S.M.A.R.T Function Set B0h, 14.40.1 S.M.A.R.T. Sub commands

Models: HTS543212L9SA00 HTS543280L9A300

1 177
Download 177 pages 15.97 Kb
Page 145
Image 145

5K320 SATA OEM Specification

14.40S.M.A.R.T Function Set (B0h)

Command Block Output Registers

 

 

 

 

 

 

 

Command Block Input Registers

 

 

 

 

 

 

 

 

 

Register

7

6

5

4

3

2

1

0

 

Register

7

6

 

5

4

3

2

 

1

0

Data

-

-

-

-

-

-

-

-

 

Data

-

-

 

-

-

-

-

 

-

-

Feature

V

V

V

V

V

V

V

V

 

Error

 

 

...See Below...

 

 

Sector Count

V

V

V

V

V

V

V

V

 

Sector Count

-

-

 

-

-

-

-

 

-

-

LBA Low

-

-

-

-

-

-

-

-

 

LBA Low

-

-

 

-

-

-

-

 

-

-

LBA Mid

0

1

0

0

1

1

1

1

 

LBA Mid

-

-

 

-

-

-

-

 

-

-

LBA High

1

1

0

0

0

0

1

0

 

LBA High

-

-

 

-

-

-

-

 

-

-

Device

-

-

-

-

-

-

-

-

 

Device

-

-

 

-

-

-

-

 

-

-

Command

1

0

1

1

0

0

0

0

 

Status

 

 

 

...See Below...

 

 

Error Register

7

6

5

4

3

2

1

0

 

CRC

UNC

0

IDN

0

ABT

T0N

AM

 

 

 

 

 

 

 

 

N

 

0

0

0

0

0

V

0

0

 

Status Register

7 6 5 4 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR

0

V

0

V

-

0

0

V

Table 110 S.M.A.R.T. Function Set Command (B0h)

The S.M.A.R.T. Function Set command provides access to Attribute Values, Attribute Thresholds and other low level subcommands that can be used for logging and reporting purposes and to accommodate special user needs. The S.M.A.R.T. Function Set command has several separate subcommands which are selectable via the device’s Features Register when the S.M.A.R.T. Function Set command is issued by the host.

14.40.1S.M.A.R.T. Sub commands

In order to select a subcommand the host must write the subcommand code to the device’s Features Register before issuing the S.M.A.R.T. Function Set command. The subcommands and their respective codes are listed below.

Code

Subcommand

D0h

S.M.A.R.T. Read Attribute Values

D1h

S.M.A.R.T. Read Attribute Thresholds

D2h

S.M.A.R.T. Enable/disable Attribute Autosave

D3h

S.M.A.R.T. Save Attribute Values

D4h

S.M.A.R.T. Execute Off-line Immediate

D5h

S.M.A.R.T. Read Log Sector

D6h

S.M.A.R.T. Write Log Sector

D8h

S.M.A.R.T. Enable Operations

D9h

S.M.A.R.T. Disable Operations

DAh

S.M.A.R.T. Return Status

DBh

S.M.A.R.T. Enable/Disable Automatic Off-Line

 

S.M.A.R.T. Read Attribute Values (Subcommand D0h)

This subcommand returns the device’s Attri bute Values to the host. Upon receipt of the S.M.A.R.T. Read Attribute Values subcommand from the host, the device saves any updated Attribute Values to the Attribute Data sectors, and then waits for the host to transfer the 512 bytes of Attribute Value information from the device.

145

Page 145
Image 145
Hitachi HTS543212L9SA00, HTS543280L9A300 manual 14.40 S.M.A.R.T Function Set B0h, 14.40.1 S.M.A.R.T. Sub commands