5K320 SATA OEM Specification

14.23Read Sector(s) Ext (24h)

Command Block Output Registers

Register

 

7

6

 

5

 

4

3

2

 

1

 

0

 

Data Low

 

-

-

 

-

 

-

-

-

 

-

 

-

 

Data High

 

-

-

 

-

 

-

-

-

 

-

 

-

 

Feature

Current

-

-

 

-

 

-

-

-

 

-

 

-

 

 

Previous

-

-

 

-

 

-

-

-

 

-

 

-

 

Sector Count

Current

V

V

 

V

 

V

V

V

 

V

 

V

 

 

Previous

V

V

 

V

 

V

V

V

 

V

 

V

 

LBA Low

Current

V

V

 

V

 

V

V

V

 

V

 

V

 

 

Previous

V

V

 

V

 

V

V

V

 

V

 

V

 

LBA Mid

Current

V

V

 

V

 

V

V

V

 

V

 

V

 

 

Previous

V

V

 

V

 

V

V

V

 

V

 

V

 

LBA High

Current

V

V

V

V

V

V

V

V

 

 

Previous

V

V

 

V

 

V

V

V

 

V

 

V

 

Device

 

-

1

 

-

 

-

-

-

 

-

 

-

 

Command

 

0

0

 

1

 

0

0

1

 

0

 

0

 

Command Block Input Registers

Register

 

7

6

 

5

 

4

3

2

 

1

 

0

Data Low

 

-

-

 

-

 

-

-

-

 

-

 

-

Data High

 

-

-

 

-

 

-

-

-

 

-

 

-

Error

 

 

 

 

...See Below...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sector Count

HOB=0

-

-

 

-

 

-

-

-

 

-

 

-

 

HOB=1

-

-

 

-

 

-

-

-

 

-

 

-

LBA Low

HOB=0

V

V

 

V

 

V

V

V

 

V

 

V

 

HOB=1

V

V

 

V

 

V

V

V

 

V

 

V

LBA Mid

HOB=0

V

V

 

V

 

V

V

V

 

V

 

V

 

HOB=1

V

V

 

V

 

V

V

V

 

V

 

V

LBA High

HOB=0

V

V

V

V

V

V

V

V

 

HOB=1

V

V

 

V

 

V

V

V

 

V

 

V

Device

 

-

-

 

-

 

-

-

-

 

-

 

-

Status

 

 

 

 

...See Below...

 

 

 

 

 

 

 

Error Register

 

 

 

7

6

5

4

3

2

1

0

 

CRC

UNC

0

IDN

0

ABT

T0N

AMN

 

0

V

0

V

0

V

0

0

 

 

 

 

Status Register

 

 

 

7

6

5

4

3

 

2

1

0

BSY

RDY

DF

DSC

DRQ

 

COR

IDX

ERR

0

V

0

V

-

 

0

0

V

Table 89 Read Sector(s) Ext Command (24h)

The Read Sector(s) Ext command reads from 1 to 65,536 sectors of data from disk media, then transfers the data from the device to the host.

The sectors are transferred through the Data Register 16 bits at a time.

If an uncorrectable error occurs, the read will be terminated at the failing sector.

Output Parameters To The Device

Sector Count Current

The number of sectors to be transferred low order, bits (7:0).

Sector Count Previous

The number of sectors to be transferred high order, bits (15:8). If 0000h in the Sector

 

Count register is specified, then 65,536 sectors will be transferred.

LBA Low Current

LBA (7:0)

LBA Low Previous

LBA (31:24)

LBA Mid Current

LBA (15:8)

LBA Mid Previous

LBA (39:32)

LBA High Current

LBA (23:16)

LBA High Previous

LBA (47:40)

Input Parameters From The Device

LBA Low (HOB=0)

LBA (7:0) of the address of the first unrecoverable error.

LBA Low (HOB=1)

LBA (31:24)of the address of the first unrecoverable error.

LBA Mid (HOB=0)

LBA (15:8)of the address of the first unrecoverable error.

LBA Mid (HOB=1)

LBA (39:32)of the address of the first unrecoverable error.

LBA High (HOB=0)

LBA (23:16)of the address of the first unrecoverable error.

LBA High (HOB=1)

LBA (47:40)of the address of the first unrecoverable error.

123

Page 123
Image 123
Hitachi HTS543212L9SA00, HTS543280L9A300 manual Read Sectors Ext 24h, Read Sectors Ext Command 24h