5K320 SATA OEM Specification

Off -line mode: The device executes command completion before executing the specified routine. During execution of the routine the device will not set BSY nor clear DRDY. If the device is in the process of performing its routine and is interrupted by a new command from the host, the device will abort or suspend its routine and service the host within two seconds after receipt of the new command. After servicing the interrupting command, the device will resume its routine automatically or not start its routine depending on the interrupting command.

Captive mode: When executing self-test in captive mode, the device sets BSY to one and executes the specified self-test routine after receipt of the command. At the end of the routine, the device sets the execution result in the Self -test execution status byte and ATA registers as below and executes command completion.

Status

Set ERR to one when self-test has failed

Error

Set ABRT to one when self -test has failed

LBA Mid

Set to F4h when self-test has failed

LBA High

Set to 2Ch when self -test has failed

SMART Selective self-test routine

When the value in the LBA Low register is 4 or 132, the Selective self -test routine shall be performed. This self-test routine shall include the initial tests performed by the Extended self -test routine plus a selectable read scan. The host shall not write the Selective self -test log while the execution of a Selective self-test command is in progress.

The user may choose to do read scan only on specific areas of the media. To do this, user shall set the test spans desired in the Selective self-test log and set the flags in the Feature flags field of the Selective self -test log to indicate do not perform off-line scan. In this case, the test spans defined shall be rea d scanned in their entirety. The Selective self -test log is updated as the self-test proceeds indicating test progress. When all specified test spans have been completed, the test is terminated and the appropriate self-test execution status is reported in the S.M.A .R.T. READ DATA response depending on the occurrence of errors. The following figure shows an example of a Selective selftest definition with three test spans defined. In this example, the test terminates when all three test spans have been scanne d.

Figure 10 Selective self-test test span example

After the scan of the selected spans described above, a user may wish to have the rest of media read scanned as an off -line scan. In this case, the user shall set the flag to enable off-line scan in addition to the other settings. If an error occurs during the scanning of the test spans, the error is reported in the self-test execution status in the S.M.A .R .T . READ DATA response and the off-line scan is not executed. When the test spans defined have been scanned, the device shall then set the offline scan pending and active flags in the Selective self -test log to one, the span under test to a value greater than five, the self-test execution status in the S .M .A .R.T. READ DATA response to 00h, set a value of 03h in the off-line data collection status in the S.M.A .R.T. READ DATA response and shall