Maintenance and Inspection
Troubleshooting
and Maintenance
6–10

Spare parts

We recommend that you stock spare parts to reduce down time, which include:

Capacitor Life Curve

The DC bus inside the inverter uses a large capacitor as shown in the diagram belo w. The
capacitor handles high voltage and current as it smooths the power for use by the
inverter. So, any degradation of the capacitor will affect the performance of the inverter.
Capacitor life is reduced in higher ambient temperatures, as the graph below demon-
strates. Be sure to keep the ambient temperature at acceptable levels, and perform
maintenance inspections on the fan, heat sink, and other components. If the inverter is
installed on a cabinet, the ambient temperature is the temperature inside the cabinet.
Part description Symbol Quantity Notes
Used Spare
Cooling fan FAN 1 1 022NF, 037LF, 015HF to
075HF
Case CV 1 1 Front case
Key cover
Case
Bottom cover
Power
Input Inverter
L1 Motor
L2
L3 Rectifier
Variable-frequency Drive
High-voltage
DC Bus
++
U
V
W
Converter
12345678910
0
10
20
30
40
-10
Operation for 12 hours / day
Ambient temperature, °C
Year s
Capacitor Life Curve
Technologies Inc.
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com