Hitachi L100 instruction manual Parameter Settings for Keypad Entry

Models: L100

1 163
Download 163 pages 3.67 Kb
Page 151
Image 151

B–4

Parameter Settings for Keypad Entry

Appendix B

 

“A” Group Parameters

Default Setting

User Setting

 

 

 

 

Func. Code

Name

-FE (Europe)

-FU (USA)

 

 

 

 

 

 

 

 

 

 

 

A43

Manual torque boost frequency

10.0

10.0

 

 

adjustment

 

 

 

 

 

 

 

 

A44

V/F characteristic curve selection

00

00

 

 

 

 

 

 

A45

V/F gain setting

100

100

 

 

 

 

 

 

A51

DC braking enable

00

00

 

 

 

 

 

 

A52

DC braking frequency setting

0.5

0.5

 

 

 

 

 

 

A53

DC braking wait time

0.0

0.0

 

 

 

 

 

 

A54

DC braking force setting

0

0

 

 

 

 

 

 

A55

DC braking time setting

0.0

0.0

 

 

 

 

 

 

A61

Frequency upper limit setting

0.0

0.0

 

 

 

 

 

 

A62

Frequency lower limit setting

0.0

0.0

 

 

 

 

 

 

A63, A65,

Jump (center) frequency setting

0.0

0.0

 

A67

 

 

 

 

 

 

 

 

 

A64, A66,

Jump (hysteresis) frequency width

0.5

0.5

 

A68

setting

 

 

 

 

 

 

 

 

A71

PID Function Enable

00

00

 

 

 

 

 

 

A72

PID proportional gain

1.0

1.0

 

 

 

 

 

 

A73

PID integral time constant

1.0

1.0

 

 

 

 

 

 

A74

PID derivative gain

0.0

0.0

 

 

 

 

 

 

A75

PV scale conversion

1.00

1.00

 

 

 

 

 

 

A76

PV source setting

00

00

 

 

 

 

 

 

A81

AVR function select

02

02

 

 

 

 

 

 

A82

AVR voltage select

230/400

230/460

 

 

 

 

 

 

A92

Second acceleration time setting

15.0

15.0

 

 

 

 

 

 

A93

Second deceleration time setting

15.0

15.0

 

 

 

 

 

 

A94

Select method to use second accel/

00

00

 

 

decel

 

 

 

 

 

 

 

 

A95

Acc1 to Acc2 frequency transition

0.0

0.0

 

 

point

 

 

 

 

 

 

 

 

A96

Dec1 to Dec2 frequency transition

0.0

0.0

 

 

point

 

 

 

 

 

 

 

 

A97

Acceleration curve selection

00

00

 

 

 

 

 

 

A98

Deceleration curve setting

00

00

 

 

 

 

 

 

Page 151
Image 151
Hitachi L100 instruction manual Parameter Settings for Keypad Entry

L100 specifications

The Hitachi L100 series is a versatile range of variable frequency drives (VFDs) designed to enhance performance in various industrial applications. Known for their reliability and efficiency, these drives are widely used in motors for pumps, fans, compressors, and conveyors.

One of the main features of the Hitachi L100 is its impressive control capabilities. The drive supports both scalar and vector control modes, allowing for precise speed and torque management. This flexibility ensures optimal motor performance across different load conditions. Additionally, the L100 series offers an impressive speed range, which can accommodate a wide variety of applications, from low-speed to high-speed requirements.

The L100 is equipped with built-in functionality for energy saving. By utilizing advanced control algorithms and auto-tuning features, the drive optimizes energy consumption, reducing operational costs and contributing to improved overall system efficiency. The energy-saving mode is particularly beneficial in applications where load conditions frequently change.

Another hallmark of the Hitachi L100 is its robust communication capabilities. The drive supports various communication protocols including Modbus and Ethernet, making it easy to integrate into existing control systems. This connectivity allows for real-time monitoring and diagnostics, which aids in predictive maintenance and minimizes downtime.

In terms of user-friendliness, the L100 series includes a clear, intuitive keypad that simplifies programming and operation. The drive also features a wide range of customizable parameters, enabling users to easily tailor the settings to suit specific application requirements. Additionally, the inclusion of a customizable PID controller allows users to refine process control automatically.

Safety is a priority in the design of the Hitachi L100. The drive comes with various built-in safety features such as overvoltage, overload, and short-circuit protection, ensuring reliable operation in challenging environments. Furthermore, it complies with global safety standards, making it suitable for international applications.

Lastly, the L100's compact design ensures easy installation and minimizes the space required in control cabinets. This is especially advantageous in facilities where space is at a premium. Overall, the Hitachi L100 series represents a combination of advanced technology, user-friendly features, and reliable performance, making it a popular choice for industrial automation solutions.