“A” Group: Standard Functions
Configuring
Drive Parameters
3–20

NOTE: For A95 and A96, if you set a very rapid Acc1 or Dec1 time (less than 1.0

second), the inverter may not be able to change rates to Acc2 or Dec2 before reaching

the target frequency. In that case, the inverter decreases the rate of Acc1 or Dec1 in order

to achieve the second ramp to the target frequency.

A96 Dec1 to Dec2
frequency transition
point
Output frequency at which
Decel1 switches to Decel2,
range is 0.0 to 360.0 Hz
0.0 Hz F-07 DEC
CHFr
A97 Acceleration curve
selection Set the characteristic curve of
Acc1 and Acc2, two options:
00...linear
01...S-curve
00 F-06 ACC
LINE
A98 Deceleration curve
setting Set the characteristic curve of
Acc1 and Acc2, two options:
00...linear
01...S-curve
00 F-07 DEC
LINE
“A” Function Run-
time
Edit
Defaults DOP,DRW,DOP+
Func.
Code Name Description EU/
US Units Func.
Code Name
Technologies Inc.
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com