Hitachi L100 THM Char CRT, Oload LVL 01.75A, Oload Const, Oload Mode on, Lock MD1, F-Samp

Models: L100

1 163
Download 163 pages 3.67 Kb
Page 157
Image 157

B–10

Parameter Settings for DOP/DRW/DOP Plus

Appendix B

Function Mode Setup

 

Displayed Default Setting

 

 

 

 

 

 

 

 

 

User Setting

Func.

Name

-FE (Europe)

-FU (USA)

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-23

Electronic thermal cut-

E-THM CHAR CRT

E-THM CHAR CRT

 

 

off characteristic

 

 

 

 

 

 

 

 

 

 

 

 

 

Electronic thermal level

E-THM LVL 01.40A

E-THM LVL 01.40A

 

 

 

(rated output current)

(rated output current)

 

 

 

 

 

 

F-24

Overload limit setting

OLOAD LVL 01.75A

OLOAD LVL 01.75A

 

 

 

(rated current * 1.25A)

(rated current * 1.25A)

 

 

 

 

 

 

 

Overload limit constant

OLOAD CONST 01.0

OLOAD CONST 01.0

 

 

 

 

 

 

 

Overload limit load

OLOAD MODE ON

OLOAD MODE ON

 

 

 

 

 

 

 

 

 

 

F-25

Software lock selection

S-LOCK

 

MD1

S-LOCK

 

MD1

 

 

 

 

 

 

F-26

Frequency lower limit

LIMIT L 000.0Hz

LIMIT L 000.0Hz

 

 

 

 

 

 

 

Frequency upper limit

LIMIT H 000.0Hz

LIMIT H 000.0Hz

 

 

 

 

 

 

F-27

Jump frequency 1

JUMP F1 000.0Hz

JUMP F1 000.0Hz

 

 

 

 

 

 

 

Jump frequency 2

JUMP F2 000.0Hz

JUMP F2 000.0Hz

 

 

 

 

 

 

 

Jump frequency 3

JUMP F3 000.0Hz

JUMP F3 000.0Hz

 

 

 

 

 

 

 

 

 

Jump frequency width

JUMP W1

00.5Hz

JUMP W1

00.5Hz

 

 

(hysteresis) 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jump frequency width

JUMP W2

00.5Hz

JUMP W2

00.5Hz

 

 

(hysteresis) 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jump frequency width

JUMP W3

00.5Hz

JUMP W3

00.5Hz

 

 

(hysteresis) 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-28

Stop key enable during

STOP-SW

ON

STOP-SW

ON

 

 

terminal mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-31

External frequency start

IN EXS

000.0Hz

IN EXS

000.0Hz

 

 

(output bias setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External frequency end

IN EXE

000.0Hz

IN EXE

000.0Hz

 

 

(output span setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External frequency start

IN EX%S

000%

IN EX%S

000%

 

 

(input bias

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External frequency start

IN EX%E

100%

IN EX%E

100%

 

 

(input span)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External frequency start

IN LEVEL

0Hz

IN LEVEL

0Hz

 

 

point (input offset)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External input filter time

IN F-SAMP

8

IN F-SAMP

8

 

 

constant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 157
Image 157
Hitachi L100 instruction manual THM Char CRT, Oload LVL 01.75A, Oload Const, Oload Mode on, Lock MD1, F-Samp

L100 specifications

The Hitachi L100 series is a versatile range of variable frequency drives (VFDs) designed to enhance performance in various industrial applications. Known for their reliability and efficiency, these drives are widely used in motors for pumps, fans, compressors, and conveyors.

One of the main features of the Hitachi L100 is its impressive control capabilities. The drive supports both scalar and vector control modes, allowing for precise speed and torque management. This flexibility ensures optimal motor performance across different load conditions. Additionally, the L100 series offers an impressive speed range, which can accommodate a wide variety of applications, from low-speed to high-speed requirements.

The L100 is equipped with built-in functionality for energy saving. By utilizing advanced control algorithms and auto-tuning features, the drive optimizes energy consumption, reducing operational costs and contributing to improved overall system efficiency. The energy-saving mode is particularly beneficial in applications where load conditions frequently change.

Another hallmark of the Hitachi L100 is its robust communication capabilities. The drive supports various communication protocols including Modbus and Ethernet, making it easy to integrate into existing control systems. This connectivity allows for real-time monitoring and diagnostics, which aids in predictive maintenance and minimizes downtime.

In terms of user-friendliness, the L100 series includes a clear, intuitive keypad that simplifies programming and operation. The drive also features a wide range of customizable parameters, enabling users to easily tailor the settings to suit specific application requirements. Additionally, the inclusion of a customizable PID controller allows users to refine process control automatically.

Safety is a priority in the design of the Hitachi L100. The drive comes with various built-in safety features such as overvoltage, overload, and short-circuit protection, ensuring reliable operation in challenging environments. Furthermore, it complies with global safety standards, making it suitable for international applications.

Lastly, the L100's compact design ensures easy installation and minimizes the space required in control cabinets. This is especially advantageous in facilities where space is at a premium. Overall, the Hitachi L100 series represents a combination of advanced technology, user-friendly features, and reliable performance, making it a popular choice for industrial automation solutions.