L100 Inverter

B–9

 

Function Mode Setup

 

Displayed Default Setting

 

 

 

 

 

 

 

 

 

 

 

 

User Setting

 

 

Func.

Name

-FE (Europe)

-FU (USA)

 

 

 

 

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-07

Deceleration time 1

DEC 1

0010.0s

DEC 1

0010.0s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deceleration time 2

DEC 2

0015.0s

DEC 2

0015.0s

 

 

 

 

 

 

 

 

 

 

 

 

 

Deceleration time

DEC CHFr 000.0Hz

DEC CHFr 000.0Hz

 

 

 

 

 

change frequency setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deceleration curve

DEC LINE

L

DEC LINE

L

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-10

Restart after FRS signal

RUN FRS

ZST

RUN FRS

ZST

 

 

Appendix

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-11

Output frequency setting

SPD FS

000.0Hz

SPD FS

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-stage 1 setting

SPD 1

000.0Hz

SPD 1

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 2 setting

SPD 2

000.0Hz

SPD 2

000.0Hz

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 3 setting

SPD 3

000.0Hz

SPD 3

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 4 setting

SPD 4

000.0Hz

SPD 4

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 5 setting

SPD 5

000.0Hz

SPD 5

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 6 setting

SPD 6

000.0Hz

SPD 6

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 7 setting

SPD 7

000.0Hz

SPD 7

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 8 setting

SPD 8

000.0Hz

SPD 8

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 9 setting

SPD 9

000.0Hz

SPD 9

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 10 setting

SPD 10

000.0Hz

SPD 10

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 11 setting

SPD 11

000.0Hz

SPD 11

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 12 setting

SPD 12

000.0Hz

SPD 12

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 13 setting

SPD 13

000.0Hz

SPD 13

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 14 setting

SPD 14

000.0Hz

SPD 14

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-speed 15 setting

SPD 15

000.0Hz

SPD 15

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-20

DC braking enable

DCB SW

OFF

DCB SW

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC braking frequency

DCB F

00.5Hz

DCB F

00.5Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC braking time delay

DCB WAIT

0.0s

DCB WAIT

0.0s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC braking force

DCB V

 

000

DCB V

 

000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC braking time

DCB T

00.0s

DCB T

00.0s

 

 

 

 

 

 

 

 

 

 

 

 

F-22

Allowable instanta-

IPS UVTIME 01.0s

IPS UVTIME 01.0s

 

 

 

 

 

neous power failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standby time after

IPS WAIT 001.0s

IPS WAIT 001.0s

 

 

 

 

 

power failure recovery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instantaneous power

IPS POWR

ALM

IPS POWR

ALM

 

 

 

 

 

failure restart selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 156
Image 156
Hitachi L100 instruction manual DEC Line, Dcb Sw Off, DCB Wait, IPS Powr ALM

L100 specifications

The Hitachi L100 series is a versatile range of variable frequency drives (VFDs) designed to enhance performance in various industrial applications. Known for their reliability and efficiency, these drives are widely used in motors for pumps, fans, compressors, and conveyors.

One of the main features of the Hitachi L100 is its impressive control capabilities. The drive supports both scalar and vector control modes, allowing for precise speed and torque management. This flexibility ensures optimal motor performance across different load conditions. Additionally, the L100 series offers an impressive speed range, which can accommodate a wide variety of applications, from low-speed to high-speed requirements.

The L100 is equipped with built-in functionality for energy saving. By utilizing advanced control algorithms and auto-tuning features, the drive optimizes energy consumption, reducing operational costs and contributing to improved overall system efficiency. The energy-saving mode is particularly beneficial in applications where load conditions frequently change.

Another hallmark of the Hitachi L100 is its robust communication capabilities. The drive supports various communication protocols including Modbus and Ethernet, making it easy to integrate into existing control systems. This connectivity allows for real-time monitoring and diagnostics, which aids in predictive maintenance and minimizes downtime.

In terms of user-friendliness, the L100 series includes a clear, intuitive keypad that simplifies programming and operation. The drive also features a wide range of customizable parameters, enabling users to easily tailor the settings to suit specific application requirements. Additionally, the inclusion of a customizable PID controller allows users to refine process control automatically.

Safety is a priority in the design of the Hitachi L100. The drive comes with various built-in safety features such as overvoltage, overload, and short-circuit protection, ensuring reliable operation in challenging environments. Furthermore, it complies with global safety standards, making it suitable for international applications.

Lastly, the L100's compact design ensures easy installation and minimizes the space required in control cabinets. This is especially advantageous in facilities where space is at a premium. Overall, the Hitachi L100 series represents a combination of advanced technology, user-friendly features, and reliable performance, making it a popular choice for industrial automation solutions.