B–8

Parameter Settings for DOP/DRW/DOP Plus

Appendix B

Monitor Mode Setup

 

Displayed Default Setting

 

 

 

 

 

 

 

User Setting

Func.

Name

-FE (Europe)

 

-FU (USA)

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mon.

Alarm display

ERR1

Under.V

ERR1

Under.V

 

 

 

 

 

 

 

 

 

 

ERR1

10.0Hz

ERR1

10.0Hz

 

 

 

 

 

 

 

 

 

 

ERR1

0.2A

ERR1

0.2A

 

 

 

 

 

 

 

 

 

 

ERR1

189.8Vdc

ERR1

189.8Vdc

 

 

 

 

 

 

 

 

ERR1 RUN 000003H

ERR1 RUN 000003H

 

 

 

 

 

 

 

Total alarm count

ERROR COUNT 002

ERROR COUNT 002

 

 

 

 

 

 

 

 

 

Trip history, previous

ERR2

Under.V

ERR2

Under.V

 

 

alarm (example)

 

 

 

 

 

 

ERR2

10.0Hz

ERR2

10.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

ERR2

0.2A

ERR2

0.2A

 

 

 

 

 

 

 

 

 

 

ERR2

189.8Vdc

ERR2

189.8Vdc

 

 

 

 

 

 

 

 

ERR2 RUN 000003H

ERR2 RUN 000003H

 

 

 

 

 

 

 

 

 

Trip history, 2nd

ERR3

#

ERR3

#

 

 

previous alarm

 

 

 

 

 

 

 

 

 

 

 

 

Function Mode Setup

 

Function Mode Setup

 

 

Displayed Default Setting

 

 

 

 

 

 

 

 

 

 

 

User Setting

 

 

Func.

Name

-FE (Europe)

-FU (USA)

 

 

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-00

Base frequency setting

F-BASE

 

050Hz

F-BASE

 

060Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-01

Maximum frequency

F-MAX

 

050Hz

F-MAX

 

060Hz

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-02

Start frequency adjust-

Fmin

0.5Hz

Fmin

0.5Hz

 

 

 

 

ment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-03

Motor input voltage

AVR AC

 

230V

AVR AC

 

230V

 

 

 

 

 

 

 

 

 

 

 

AVR function for decel-

AVR MODE DOFF

AVR MODE DOFF

 

 

 

 

eration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F-04

Control method setting

CONTROL

VC

CONTROL

VC

 

 

 

 

 

 

 

 

 

 

 

 

F-06

Acceleration time 1

ACC 1

0010.0s

ACC 1

0010.0s

 

 

 

 

 

 

 

 

 

 

 

 

 

2-stage acceleration time

ACC CHG

TM

ACC CHG

TM

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceleration time 2

ACC 2

0015.0s

ACC 2

0015.0s

 

 

 

 

 

 

 

 

 

 

 

Acceleration time

ACC CHFr 000.0Hz

ACC CHFr 000.0Hz

 

 

 

 

change frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceleration curve

ACC LINE

L

ACC LINE

L

 

 

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 155
Image 155
Hitachi L100 instruction manual Function Mode Setup

L100 specifications

The Hitachi L100 series is a versatile range of variable frequency drives (VFDs) designed to enhance performance in various industrial applications. Known for their reliability and efficiency, these drives are widely used in motors for pumps, fans, compressors, and conveyors.

One of the main features of the Hitachi L100 is its impressive control capabilities. The drive supports both scalar and vector control modes, allowing for precise speed and torque management. This flexibility ensures optimal motor performance across different load conditions. Additionally, the L100 series offers an impressive speed range, which can accommodate a wide variety of applications, from low-speed to high-speed requirements.

The L100 is equipped with built-in functionality for energy saving. By utilizing advanced control algorithms and auto-tuning features, the drive optimizes energy consumption, reducing operational costs and contributing to improved overall system efficiency. The energy-saving mode is particularly beneficial in applications where load conditions frequently change.

Another hallmark of the Hitachi L100 is its robust communication capabilities. The drive supports various communication protocols including Modbus and Ethernet, making it easy to integrate into existing control systems. This connectivity allows for real-time monitoring and diagnostics, which aids in predictive maintenance and minimizes downtime.

In terms of user-friendliness, the L100 series includes a clear, intuitive keypad that simplifies programming and operation. The drive also features a wide range of customizable parameters, enabling users to easily tailor the settings to suit specific application requirements. Additionally, the inclusion of a customizable PID controller allows users to refine process control automatically.

Safety is a priority in the design of the Hitachi L100. The drive comes with various built-in safety features such as overvoltage, overload, and short-circuit protection, ensuring reliable operation in challenging environments. Furthermore, it complies with global safety standards, making it suitable for international applications.

Lastly, the L100's compact design ensures easy installation and minimizes the space required in control cabinets. This is especially advantageous in facilities where space is at a premium. Overall, the Hitachi L100 series represents a combination of advanced technology, user-friendly features, and reliable performance, making it a popular choice for industrial automation solutions.