B–25

L200 Inverter

The following table lists the holding registers for the “A” Group Standard Functions.

 

 

Holding Registers for “A” Group Standard Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Func.

Name

R/W

Description

 

Network Data

 

 

 

 

 

 

 

 

 

 

 

 

Code

Reg.

 

Range

 

Res.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A001

Frequency source

R/W

Five options; select codes:

002Dh

 

0 to 3, 10

 

 

 

 

 

setting

 

00... Keypad potentiometer

 

 

 

 

 

 

 

 

 

 

 

01... Control terminal

 

 

 

 

 

 

 

 

 

 

 

02... Function F001 setting

 

 

 

 

 

 

 

 

 

 

 

03... ModBus network input

 

 

 

 

 

 

 

 

 

 

 

10... Calculate function output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

A002

Run command source

R/W

Three options; select codes:

002Eh

 

1, 2, 3

 

 

 

 

setting

 

03... ModBus network input

 

 

 

 

 

 

 

 

 

01... Control terminal

 

 

 

 

 

 

 

 

 

 

 

02... Run key on keypad, or

 

 

 

 

 

 

 

 

 

 

 

digital operator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

A003

Base frequency setting

R/W

Settable from 30 Hz to the

002Fh

 

30 to

 

1 Hz

 

 

 

 

 

 

 

 

 

 

maximum frequency

 

 

max. freq.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A203

Base frequency setting,

R/W

Settable from 30 Hz to the 2nd

0030h

 

30 to

 

1 Hz

 

 

 

 

2nd motor

 

maximum frequency

 

 

max. freq.

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A004

Maximum frequency

R/W

Settable from the base

0031h

 

30 to 400

 

1 Hz

 

 

 

 

setting

 

frequency up to 400 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A204

Maximum frequency

R/W

Settable from the 2nd base

0032h

 

30 to 400

 

1 Hz

 

 

 

 

setting, 2nd motor

 

frequency up to 400 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A005

[AT] selection

R/W

Four options, select codes:

0033h

 

0, 1, 2, 3

 

 

 

 

 

 

 

00... Select between [O] and

 

 

 

 

 

 

 

 

 

 

 

[OI] at [AT]

 

 

 

 

 

 

 

 

 

 

 

01... [O] + [OI] ([AT] input is

 

 

 

 

 

 

 

 

 

 

 

ignored)

 

 

 

 

 

 

 

 

 

 

 

02... Select between [O] and

 

 

 

 

 

 

 

 

 

 

 

keypad potentiometer

 

 

 

 

 

 

 

 

 

 

 

03... Select between [OI] and

 

 

 

 

 

 

 

 

 

 

 

keypad potentiometer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A011

Pot./O–L input active

R/W

The output frequency corre-

0034h

 

0 to 4000

 

0.1 Hz

 

 

 

 

range start frequency

 

sponding to the analog input

 

 

 

 

 

 

 

 

 

 

 

range starting point,

 

 

 

 

 

 

 

 

 

 

 

range is 0.0 to 400.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A012

Pot./O–L input active

R/W

The output frequency corre-

0035h

 

0 to 4000

 

0.1 Hz

 

 

 

 

range end frequency

 

sponding to the analog input

 

 

 

 

 

 

 

 

 

 

 

range ending point,

 

 

 

 

 

 

 

 

 

 

 

range is 0.0 to 400.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A013

Pot./O–L input active

R/W

The starting point (offset) for

0036h

 

0 to 100

 

1 %

 

 

 

 

range start voltage

 

the active analog input range,

 

 

 

 

 

 

 

 

 

 

 

range is 0. to 100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A014

Pot./O–L input active

R/W

The ending point (offset) for

0037h

 

0 to 100

 

1 %

 

 

 

 

range end voltage

 

the active analog input range,

 

 

 

 

 

 

 

 

 

 

 

range is 0. to 100.