C–7

L200 Inverter

Fine Tuning Functions

 

 

“B” Group Parameters

Default Setting

User

 

 

 

 

 

 

 

 

 

Func.

 

-FEF

-FU

 

 

 

Name

Setting

 

 

Code

(EU)

(USA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B001

Selection of automatic restart

00

00

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B002

Allowable under-voltage power

1.0

1.0

 

 

 

 

 

failure time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B003

Retry wait time before motor

1.0

1.0

 

 

 

 

 

restart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B004

Instantaneous power failure /

00

00

 

 

 

 

 

under-voltage trip alarm enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B005

Number of restarts on power

00

00

 

 

 

 

 

failure / under-voltage trip events

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B012

Level of electronic thermal

Rated

Rated

 

 

 

 

 

setting

current for

current for

 

 

 

 

 

 

each

each

 

 

 

 

 

 

 

 

 

 

 

 

inverter

inverter

 

 

 

 

 

 

 

 

 

 

 

 

B212

Level of electronic thermal

Rated

Rated

 

 

Appendix

 

 

setting, 2nd motor

current for

current for

 

 

 

 

 

 

 

 

 

 

each

each

 

 

 

 

 

 

inverter

inverter

 

 

 

 

 

 

 

 

 

 

 

 

B013

Electronic thermal characteristic

01

01

 

 

C

 

 

 

 

 

 

 

 

B213

Electronic thermal characteristic,

01

01

 

 

 

 

 

2nd motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B021

Overload restriction operation

01

01

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B022

Overload restriction setting

Rated

Rated

 

 

 

 

 

 

current x

current x

 

 

 

 

 

 

1.5

1.5

 

 

 

 

 

 

 

 

 

 

 

 

B023

Deceleration rate at overload

1.0

30.0

 

 

 

 

 

restriction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B031

Software lock mode selection

01

01

 

 

 

 

 

 

 

 

 

 

 

 

B032

Reactive current setting

100

100

 

 

 

 

 

 

 

 

 

 

 

 

B080

[AM] analog signal gain

100.

100.

 

 

 

 

 

 

 

 

 

 

 

 

B082

Start frequency adjustment

0.5

0.5

 

 

 

 

 

 

 

 

 

 

 

 

B083

Carrier frequency setting

5.0

5.0

 

 

 

 

 

 

 

 

 

 

 

 

B084

Initialization mode (parameters

00

00

 

 

 

 

 

or trip history)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B085

Country code for initialization

01

02