Honeywell MS4103 manual Properties of Saturated Steam Boiling Point or, Maximum, For valve, Gage

Models: MS4103

1 268
Download 268 pages 21 Kb
Page 262
Image 262

Appendix A: Valve Selection and Sizing

LINEAR VALVE under VALVE SELECTION for more infor- mation.

 

100%

 

 

Cv = 25

 

 

 

 

 

 

 

 

 

 

OPENING/

 

Cv = 41

 

 

 

 

 

 

 

 

 

 

 

FLOW

 

 

 

 

 

 

 

STEAM

 

 

 

 

 

 

 

VALVE

 

 

LINEAR VALVE

 

 

 

 

 

CHARACTERISTIC

 

 

 

 

 

 

 

 

 

 

0%

 

 

100%

 

 

 

 

 

STEM TRAVEL

 

 

 

 

 

 

C2337

 

Fig. 20. Effect of Pressure Drop in Steam Valve Sizing.

Table 5. Properties of Saturated Steam.

 

 

 

 

 

 

 

 

 

 

Boiling

 

 

 

 

 

 

Point or

 

 

 

 

 

 

Steam

 

 

V

Maximum

Vacuum,

Temp-

 

Specific

Allowable

Inches of

erature

 

Volume (V),

(For valve

Pressure

Mercury

(Deg F)

 

cu. ft/lb

sizing)

Drop, psi.

 

 

 

 

 

 

 

 

29

76.6

 

 

706.00

26.57

0.23

25

133.2

 

 

145.00

12.04

1.2

20

161.2

 

 

75.20

8.672

2.4

15

178.9

 

 

51.30

7.162

3.7

14

181.8

 

 

48.30

6.950

3.9

 

 

 

 

 

 

 

 

12

187.2

 

 

43.27

6.576

4.4

10

192.2

 

 

39.16

6.257

4.9

8

196.7

 

 

35.81

5.984

5.4

6

201.0

 

 

32.99

5.744

5.9

4

204.8

 

 

30.62

5.533

6.4

2

208.5

 

 

28.58

5.345

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiling

 

 

 

 

 

 

Point or

 

 

 

 

 

 

Steam

 

 

V

Maximum

Gage

Temp-

 

Specific

Allowable

Pressure,

erature

 

Volume (V),

(For valve

Pressure

psig

(Deg F)

 

cu. ft/lb

sizing)

Drop, psi.

 

 

 

 

 

 

 

 

0

212.0

 

 

26.79

5.175

7.4

1

215.3

 

 

25.20

5.020

7.8

2

218.5

 

 

23.78

4.876

8.4

3

221.5

 

 

22.57

4.751

8.8

4

224.4

 

 

21.40

4.626

9.4

 

 

 

 

 

 

 

 

5

227.1

 

 

20.41

4.518

9.8

6

229.8

 

 

19.45

4.410

10.4

7

232.3

 

 

18.64

4.317

10.8

8

234.8

 

 

17.85

4.225

11.4

9

237.1

 

 

17.16

4.142

11.8

 

 

 

 

 

 

 

 

 

Steam

 

V

Maximum

Gage

Temp-

Specific

Allowable

Pressure,

erature

Volume (V),

(For valve

Pressure

psig

(Deg F)

cu. ft/lb

sizing)

Drop, psi.

 

 

 

 

 

10

239.4

16.49

4.061

12.4

11

241.6

15.90

3.987

12.8

12

243.7

15.35

3.918

13.4

15

249.8

13.87

3.724

14.8

20

258.8

12.00

3.464

17.4

 

 

 

 

 

25

266.8

10.57

3.251

19.8

30

274.0

9.463

3.076

22.4

35

280.6

8.56

2.93

24.8

40

286.7

7.826

2.797

27.4

45

292.4

7.209

2.685

29.8

 

 

 

 

 

50

297.7

6.682

2.585

32.4

55

302.6

6.232

2.496

34.8

60

307.3

5.836

2.416

37.4

65

311.8

5.491

2.343

39.8

70

316.0

5.182

2.276

42.4

 

 

 

 

 

75

320.0

4.912

2.216

44.8

80

323.9

4.662

2.159

47.4

85

327.6

4.445

2.108

49.8

90

331.2

4.239

2.059

52.4

95

334.6

4.060

2.015

54.8

 

 

 

 

 

100

337.9

3.888

1.972

57.4

110

344.1

3.595

1.896

62.3

120

350.0

3.337

1.827

67.4

130

355.2

3.12

1.766

72.3

140

360.9

2.923

1.710

77.4

 

 

 

 

 

150

366.2

2.746

1.657

82.3

160

370.6

2.602

1.613

87.4

170

375.5

2.462

1.569

92.3

180

379.6

2.345

1.531

97.4

190

383.9

2.234

1.495

102.3

 

 

 

 

 

200

387.8

2.134

1.461

107.4

225

397.4

1.918

1.385

119.8

250

406.0

1.742

1.320

132.4

275

414.2

1.595

1.263

145.0

300

421.8

1.472

1.213

157.4

 

 

 

 

 

350

435.6

1.272

1.128

182.4

400

448.1

1.120

1.058

207.4

450

459.5

0.998

0.999

232.4

500

470.0

0.900

0.949

257.4

550

479.7

0.818

0.904

282.4

 

 

 

 

 

600

488.8

0.749

0.865

307.4

650

497.3

0.690

0.831

332.4

700

505.4

0.639

0.799

357.4

800

520.3

0.554

0.744

407.4

900

533.9

0.488

0.699

457.4

1000

546.3

0.435

0.659

507.4

 

 

 

 

 

262