Contents
Heating Controller SDC Remote Heating Controller DHC
EN2H-0220GE51 R0308
Contents
Contents
Log
SDC / DHC
Page
Software version
Intended use
Connection conditions
Power supply
Cable installation
Cable cross-sections
Hot-water temperature greater than 60 C
Grounding and zeroing
SDC / DHC
SDC 12-31
Type
Burnerstage 2 or Districtheating valve Closed
Operation
Display and operating elements
Display basic display
Setting range
Daytime room temperature button
Factory setting
Operating elements Input button press / turn
Daytime hot-water temperature button
Night-time room temperature button
Setting
Factory setting 50 C
Operating mode button basic display
Absent
2.5.1 Setting Application
Absence mode short-term program
Party mode short-term program
P1 P2, P3
Automatic mode
Enabling
Display Disabling / enabling default program P2 to P3
Disabling / enabling default programs P2 to P3
Manual summer operation excluding heating operation
Continuous heating operation
Continuous lowering operation
Standby mode
Switching time programs / Holiday programs button
Holiday mode
Factory setting Current date
System information button
Operating overview
Setting range Factory setting
Manual mode / Emission measurement button
Cancellation
2.9 Setting Setting range Heating curve
Menu-selection level
Menu functions are described in the following
Returning
Access
Time Date menu
Timeprograms menu Access Returning
Selection of day of the week and cycle
Selection of the control circuit
Selection of the program
Switch-off time
Cycle temperature
Switching time programming programs P2 and P3 disabled
DHW
Default switching time program P1 for heating and hot water
Default program P1
Switching time programming program P2 and P3 enabled
Default program P2
Default program P3
Copying switching time programs days Source day Target day
Calling up the copy function days
Calling up the copy function heating circuits
Block programming
SDC / DHC
Copying heating circuits
Reloading default programs
SDC / DHC
Reloading default programs
Switching time programs P2 and P3 enabled
Factory setting German
System Parameters menu Access Returning
Setting values DE
Language selection
Set values
Operating mode Setting range Set values
Time program
30 C
Summer / Heating limit
Quick increase in outside temperature
Slow increase in outside temperature
Undoing deactivation
Factory setting 20 C
Parameter reset
DHW menu
Night-time hot-water temperature
Factory setting 40 C
Reduced operation
Set values RED lowering operation
ECO switch-off operation
Heating system
Radiator systems
Log
Time Setpoint Opt Wed Cont. circuit Thu Fri Sat Sun
SDC / DHC
SDC / DHC
Page