4.2.2.1Selection of the control circuit

After accessing the "Timeprograms" menu, the desired control circuits can be selected with the input button î in the following sequence:

Direct heating circuit (HC)

Mixed heating circuit 1 (MC-1)

Mixed heating circuit 2 (MC-2)

Hot-water circuit (DHW)

► Press input button î to access the selected circuit.

4.2.2.2Selection of the program

If the switching time programs P2 and P3 have been enabled (see "System Parameter" menu, program parameter = P1 to P3), the program selection appears.

If switching time programs P2 and P3 are disabled, program selection is automatically skipped (see "System Parameters" menu, program parameter = P1).

4.2.2.3Selection of day of the week and cycle

Once the program is selected, the first cycle of the first day of the week (MO 1) and the relevant section in the top time bar flash. The other cycles are selected by turning the input button î and confirmed by pressing the input button î.