7.Stacking Remote Condenser Unit

3)Install a ground wire from the icemaker fan motor junction box to the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating.

4)Install line and neutral wires from the fan motor leads in the icemaker fan motor junction box to the leads in the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating.

5)Replace the junction box covers and the louver panel in their correct positions.

7.Stacking Remote Condenser Unit

1)Install the lower remote condenser unit as described earlier in this section.

2)Place the upper remote condenser unit on top of the lower. See Fig. 16.

3)Secure the upper remote condenser unit to the lower remote condenser unit with the

4 screws provided.

4)Install refrigerant lines and make electrical connection as described earlier in this section.

Upper Remote

Condenser Unit

Screws Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundScrews

Lower Remote

Condenser Unit

Fig. 16