Hoshizaki MRH, MWH KML-451MAH, MWH KML-631MAH, KML-250MAH, MWH KML-351MAH H. Final Checklist

Models: MWH KML-351MAH KML-250MAH MWH KML-631MAH MWH MRH MWH KML-451MAH

1 40
Download 40 pages 33.48 Kb
Page 31
Image 31
H. Final Checklist

H. Final Checklist

Manual background WARNING

CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/ice storage bin.

1)Is the icemaker level?

2)Is the icemaker in a site where the ambient temperature is within 45°F to 100°F (7°C to 38°C) and the water temperature within 45°F to 90°F (7°C to 32°C) all year around?

3)Is there at least 6" (15 cm) clearance at rear, sides, and top of the icemaker?

4)Have the shipping carton, tape, and packing material been removed from the icemaker? Is the cube guide in the correct position?

5)Have all electrical and water connections been made? Do electrical and water connections meet all national, state, and local code and regulation requirements?

6)Has the power supply voltage been checked or tested against the nameplate rating? Has a proper ground been installed to the icemaker? On remote model, has a proper ground also been installed to the remote condenser unit?

7)Are the water supply and drain lines sized as specified? Are the water supply line

shut‑off valve(s) and drain valve(s) installed? Has the water supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG?

8)Have the refrigerant lines been checked to make sure they do not rub or touch other lines or surfaces? Has the fan blade (if applicable) been checked to make sure it turns freely?

9)On remote model:

Is the line set sized as specified, insulated, tightened, and free of leaks and kinks?

If the line set exceeds 66 feet (20 m), has the charge been adjusted as specified?

Has the icemaker power supply been on for a minimum of 4 hours?

Is the remote condenser unit in a site where the ambient temperature is within

-20°F to +122°F (-29°C to +50°C) all year around?

Is there at least 24" (61 cm) clearance around the remote condenser unit?

10)Are all components, fasteners, and thumbscrews securely in place?

11)Has the end user been given the instruction manual, and instructed on how to operate the icemaker and the importance of the recommended periodic maintenance?

12)Has the end user been given the contact information of an authorized service agent?

13)Has the warranty card been filled out and forwarded to the factory for warranty registration?

31

Page 31
Image 31
Hoshizaki MRH, MWH KML-451MAH, MWH KML-631MAH, KML-250MAH, MWH KML-351MAH instruction manual H. Final Checklist