Hoshizaki MRH, MWH IV. Preparing the Icemaker for Periods of Non-Use, Drain the water tank

Models: MWH KML-351MAH KML-250MAH MWH KML-631MAH MWH MRH MWH KML-451MAH

1 40
Download 40 pages 33.48 Kb
Page 37
Image 37
IV. Preparing the Icemaker for Periods of Non-Use

IV. Preparing the Icemaker for Periods of Non-Use

NOTICE

When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage.

To prevent damage to the water pump, do not leave the control switch in the "SERVICE" position for extended periods when the water tank is empty.

When the icemaker is not used for two or three days under normal conditions, it is sufficient to move the control switch to the "OFF" position. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below.

1.Remove the water from the icemaker water supply line:

1)Turn off the power supply, then remove the front panel.

2)Move the control switch to the "OFF" position.

3)Close the icemaker water supply line shut-off valve, then open the icemaker water supply line drain valve.

4)Allow the line to drain by gravity.

5)Attach a compressed air or carbon dioxide supply to the icemaker water supply line drain valve.

6)Move the control switch to the "ICE" position.

7)Replace the front panel in its correct position, then turn on the power supply.

8)Blow the icemaker water supply line out using the compressed air or carbon dioxide supply.

9)Close the icemaker water supply line drain valve.

2.Drain the water tank:

1)Turn off the power supply, then remove the front panel.

2)Move the service switch to the "DRAIN" position, then move the control switch to the "SERVICE" position.

3)Replace the front panel in its correct position, then turn on the power supply for 2 minutes.

4)Turn off the power supply, then remove the front panel.

5)Move the control switch to the "OFF" position.

6)Replace the front panel in its correct position.

7)Remove all ice from the dispenser unit/ice storage bin. Clean the dispenser unit/ice storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.

3.On water-cooled model, remove the water from the water-cooled condenser:

1)Make sure the power supply is off, then remove the front, top, and right side panels.

2)Close the condenser water supply line shut-off valve. If connected to a closed loop system, also close the condenser return line shut-off valve.