Hoshizaki MWH KML-451MAH, MRH, MWH KML-631MAH, KML-250MAH, MWH KML-351MAH 6Close the drain valves

Models: MWH KML-351MAH KML-250MAH MWH KML-631MAH MWH MRH MWH KML-451MAH

1 40
Download 40 pages 33.48 Kb
Page 38
Image 38

3)Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve.

4)Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.

5)Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring. While holding the valve open, blow out the condenser using the compressed air or carbon dioxide supply until water stops coming out.

6)Close the drain valve(s).

7)Replace the right side, top, and front panels in their correct positions.