Operating the Fibre Bridge

Changing the Default Settings

Changing the Default Settings

The basic Fibre Bridge configuration assumes there is only one Fibre Bridge included in the system. If this is a DLT installation and more than one Fibre bridge will be installed, or if there is another Fibre Channel device using the same address, you must change the fibre channel address, using the serial port of the Fibre Bridge.

Connecting the Serial Cable

Using the serial cable is not necessary in most installations. The default settings work in most configurations. Use the serial cable only if one of the following situations occurs:

The default configuration must be changed.

A failure has occurred that requires diagnostic procedures. See “Chapter 4: Troubleshooting.”

If any of these scenarios occur, attach the serial cable and RJ-11 to DB9 adapter as shown in Figure 3-2 on page 3-6.

1.Plug the RJ-11 connector into the Fibre Bridge.

2.Plug the DB9 adapter into the Com1 or Com2 port of the computer.

3.Verify that the RJ-11 serial cable is properly plugged into the RJ-11 to DB9 adapter.

the Operating Bridge Fibre

Chapter 3

3-5