NOTE

NOTE

NOTE

Operating the Fibre Bridge

Changing the Default Settings

Serial Port Setup

Before communicating, the PC serial port must be connected to the Fibre Bridge and terminal emulation software (Hyperterminal, or similar) must be installed on the host. Configure the terminal emulation program to use the settings in Table 3-1 on page 3-8for the PC’s serial port.

When initially powered on, the Fibre Bridge uses the default (or previously set) baud rate during self-tests. After completing the self-tests, pressing ENTER several times causes the Fibre Bridge to reset itself to the baud rate used by the host.

Serial Port Operation

BridgeFibre

theOperating

 

 

The serial port on the Fibre Bridge connects to a terminal or computer

 

 

that is running a terminal emulator such as Hyperterminal on Windows

 

 

NT. The operator can then perform the following:

 

 

• Change the system addresses and address modes

 

 

• Check the results of the POST tests

 

 

 

 

• Change the operating level of diagnostic routines

 

 

The serial port cannot be used to transfer data to devices on the SCSI

 

 

buses or on the Fibre Channel loop.

 

 

An EEPROM inside the Fibre Bridge stores configuration changes.

 

 

Because the Fibre Bridge stores its original settings, it can be reset to the

 

 

original configuration at any time. See Table 3-1 on page 3-8for the

 

 

default configuration settings.

 

 

If there is trouble communicating between the serial port and the Fibre

 

 

Bridge, contact an HP service representative.

 

 

Chapter 3

3-7