Formatter PCA

WARNING! ESD sensitive component.

1.Remove the following components:

Tray 2 cassette

Left cover. See Left cover on page 11.

Wireless PCA (wireless models only). See Wireless PCA on page 48.

2.On the left side of the product, disconnect any connectors and flat cables (callout 1) on the formatter, and then remove four screws (callout 2).

Figure 1-65Remove the formatter

2

1

NOTE: Wireless models only: The screw in the upper-right corner also fastens the wireless PCA holder to the formatter PCA. Keep this screw, which is longer, with the holder for reinstallation.

Wireless PCA

NOTE: This section applies to wireless models only.

The wireless PCA is located at the top of the formatter PCA.

1.Remove the following components:

Tray 2 cassette

Left cover. See Left cover on page 11.

48 Chapter 1 Removal and replacement

ENWW