Interface Modules
1xT1 Interface Module
The 1xT1 Interface Module (see Figure 5) provides a T1 (full T1 or fractional T1) WAN interface for the ProCurve Secure Router. Refer to Table
Figure 5. 1xT1 Interface Module
Features and Specifications
Operating Modes
•T1/FT1 Frame Relay/Multilink Frame Relay
•T1/FT1 PPP/Multilink PPP
•T1/FT1 HDLC
T1/FT1 Interface
•Supported Standards: AT&T TR 62411, AT&T TR 54016, ANSI T1.403, Bellcore TR 194
•Line Rate: 1.544 Mbps +75 bps
•Line Code: AMI or B8ZS
•Framing: D4 (SF) or ESF
•FT1 Line Rate: DS0 channelized
•Input Signal: 0 to
•Line
•Connector:
•DS0 Assignment: Programmable
Clock Source
•Network
•Internal
Physical
•Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Diagnostics
•Test Pattern Generation and Detection: 511, QRSS, all ones, all zeros
•Network loopbacks (local and remote); responds to both inband and FDL loop codes
•Alarm generation and detection
•Network and user sets of performance data (15 minutes and 24 hours)
Compliance
•ACTA/FCC Part 68, IC
•UL/CUL 60950, IEC 60950
•EMC - see Electromagnetic Compatibility (EMC) Table on page 62
Environmental
•Operating Temperature: 0°C to 50°C (32°F to 122°F)
•
•Relative Humidity: Up to 95 percent noncondensing at 30°C (86°F)
•
•Altitude: Up to 3.05 km (10,000 ft)
Copyright 2006 | 19 |