ProCurve Secure Router Installation Guide | Option Modules |
|
|
2xT1 Interface Module
The 2xT1 Interface Module (see Figure 7) provides two T1 interfaces for the ProCurve Secure Router. The module provides up to 1.544 Mbps on each network interface. Refer to Table
Figure 7. 2xT1 Interface Module
eatures and Specifications
Operating Modes
•T1/ FT1 Frame Relay/Multilink Frame Relay
•T1/FT1 PPP/Multilink PPP
•T1/FT1 HDLC
T1 Interface
•Supported Standards: AT&T TR 62411, AT&T TR 54016, Bellcore TR 194, ANSI T1.403
•Line Rate: 1.544 Mbps +75 bps
•Line Code: AMI or B8ZS
•Framing: D4 (SF) or ESF
•FT1 Line Rate: DS0 channelized
•Input Signal: 0 to
•Line
•Connector:
•DS0 Assignment: Programmable
Clock Source
•Network
•Internal
•Through
Physical
•Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Diagnostics
•Test Pattern Generation and Detection: QRSS, 511,
•Network loopbacks (local and remote); responds to both inband and FDL loop codes (T1 interface only)
•Alarm generation and detection
•Network performance data (15 minutes and 24 hours)
Compliance
•ACTA/FCC Part 68, IC
•UL/CUL 60950, IEC 60950
•EMC - refer to Electromagnetic Compatibility (EMC) Table on page 62.
Environmental
•Operating Temperature: 0°C to 50°C (32°F to 122°F)
•
•Relative Humidity: Up to 95 percent noncondensing at 30°C (86°F)
•
•Altitude: Up to 3.05 km (10,000 ft)
Note | The 2xT1 module supports a single clock source for both T1 interfaces. Changing the |
| clock source on one T1 interface automatically affects the configuration of the other T1 |
| interface. For example, setting the clock to line on the first T1 configures the clock source |
| of the second T1 as through. |
|
|
Copyright 2006 | 21 |