Option Modules

ProCurve Secure Router Installation Guide

 

 

1xADSL2+ Annex A Interface Module

The 1xADSL2+ Annex A Interface Module (see Figure 12) adds ADSL capability to the ProCurve Secure Router. Performance information is provided below. Refer to Table A-8 on page 46 for the pinouts. Refer to Table A-12 on page 47 for the backup connector pinouts. An optional backup module is required for backup applications.

Figure 12. 1xADSL2+ Annex A Interface Module

Features and Specifications

 

ADSL Interface

ADSL1 Performance

ADSL over POTS, Annex A

Supported Standards:

ITU G.992.1 – Annex A (G.dmt)

ITU G.992.2 – Annex A (G.lite)

ITU G.992.3 – Annex A ADSL2 (G.dmt.bis)

ITU G.992.3 – Annex L READSL2

ITU G.992.5 – Annex A ADSL2+

ANSI T1.413 Issue 2

Connector: RJ-11 (6-pin jack, inner pair)

ATM

Multiple Protocol over AAL5 (RFC2684)

ATM Forum UNI 3.1/4.0 PVC

Up to 16 Virtual Circuits

ATM Class of Service (UBR)

PPP over ATM (RFC2364)

PPP over Ethernet (RFC2516)

ATM F5 OAM

Compliance

ACTA/FCC Part 68, IC CS-03, AS/ASIF S043, AS/ACIF S002

EN 60950, IEC 60950, UL/CUL 60950, AS/NZS 60950

EMC - see Electromagnetic Compatibility (EMC) Table on page 62

Max = 8 Mbps downstream and 800 kbps upstream

Min = 224 kbps downstream and 32 kbps upstream

ADSL2 Performance

Max = ~12 Mbps downstream and ~1 Mbps upstream

Min = 224 kbps downstream and 32 kbps upstream

ADSL2+ Performance*

Max = ~24.5 Mbps downstream and up to 2 Mbps upstream

Min = 224 kbps downstream and 32 kbps

upstream

*ADSL2+ support is planned in a future software update.

Environmental

Operating temperature: 0°C to 50°C (32°F to 122°F)

Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)

Relative Humidity: Up to 95 percent noncondensing at 30°C (86°F)

Non-Operating Relative Humidity: Up to 95 percent noncondensing at 30°C (86°F)

Altitude: Up to 3.05 km (10,000 ft)

Physical

Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D

26

Copyright 2006 Hewlett-Packard Development Company, LP

5990-3760