POST Error Messages
Numeric Codes and Text Messages (Continued)
Code/Message | Probable Cause | Recommended Action | |
|
|
|
|
Hard drive is about | 1. | Determine if hard drive is giving | |
Drive Detects | to fail. (Some hard drives |
| correct error message. Enter |
Imminent Failure | have a hard drive |
| Computer Setup and run the Drive |
| firmware patch that will |
| Protection System test under |
| fix an erroneous error |
| Storage > DPS |
| message.) | 2. | Apply hard drive firmware patch |
|
| ||
|
|
| if applicable. (Available at |
|
|
| |
|
| 3. | Back up contents and replace hard |
|
|
| drive. |
|
|
|
|
(for Multibay option/ | 1. | Ensure the Multibay option is | |
incorrectly installed |
| attached as device 0 on the IDE | |
| 1. Multibay option |
| cable. |
| 2. | Ensure no other device is attached to | |
| ribbon cables not | ||
| seated or improperly |
| the same IDE cable. |
| attached. | 3. | Ensure both ends of the IDE and |
|
| ||
| 2. Multibay device not |
| Multibay ribbon cables are properly |
| properly seated. |
| seated. |
| 3. Multibay diskette | 4. | Ensure the Multibay device is fully |
| present. |
| inserted. |
|
| 5. | Ensure a Multibay diskette is not |
|
|
| present (Multibay diskette drives are |
|
|
| not supported by the Multibay |
|
|
| option). |
|
|
|
|
| (for integrated Multibay/ | 1. | Ensure the Multibay device is fully |
| USDT systems) |
| inserted. |
| 1. Multibay device not | 2. | Ensure the Multibay riser is properly |
| properly seated. |
| seated. |
2. Multibay riser not properly seated.
www.hp.com | Troubleshooting Guide |