Creating Labels Using Internal Batach Software
To format the module hit "I" and the following screen will appear:
MODULE MEMORY TEST AND FORMAT
WARNING !! MODULE DATA WILL BE LOST !!
PLUG IN MODULE. PRESS ENTER (Esc TO CANCEL)
Hit "Enter" to begin formatting the module, the following screen will appear:
MODULE MEMORY TEST AND FORMAT
WARNING !! MODULE DATA WILL BE LOST !! MODULE UNDER TEST PLEASE WAIT !!
ppppppppvvvvvvvv
MODULE MEMORY IS GOOD
PRESS ENTER TO TEST ANOTHER "Esc TO EXIT"
once the module has been formatted, hit "Esc" to enter the Internal Batch Mode.
Note: Use a small screwdriver to turn the module's write protect switch to the ‘off’ position. Label formats cannot be sent to the module if the switch is in the ‘on’ position. To prevent accidental changes or modifications to formats, turn the write protect switch back to the ‘on’ position.
4.Verify Setup, Power Up, and Load Media
Check that all connections are made and that DIP Switch S1 is correctly configured. Turn on the CRT and Printer power switches. Press the F1 key on the CRT several times. The create/modify label screen and print label screen should toggle back and forth. If this does not happen,
DMX 400/430 Operator’s Manual | 29 |