Motion Adjust (Carriage Scan Alignment)1.Press Select Alignment Plot.2.Browse to the c:\Ioline\Calibration folder. Select the 40X8.plt test file.3.The Motion Adjust box has one number for adjustment. The default value is 0.

4.Changing the values affects the next scan, created when moving from left to right.

5.Press the Set Motion button after making adjustments to the values.

Example:

Figure 32. The Motion

Adjust Box.

Chapter 4: Routine Maintenance 45

iNote

Adding (+) numbers moves the second scan left.

Subtracting (-) moves the second scan right.

a.Lines from the second scan shift left to align with the first scan.

b.Decrease the Motion Adjust value by 1.

c.Press the Set Motion button.

d.Repeat the test until alignment is correct.

6.Click on Done when finished.

Frame Gap (Paper ScanAlignment)1.Press Select Alignment Plot.

2.Browse to the c:\Ioline\Calibration folder. Select the 40X8.plt test file.

3.The Frame Gap box has one number for adjustment. The default value is 0.

4.Changing the values affects the next scan, created when moving paper forward through the printer.

5.Press the Set Gap button after mak- ing adjustments to the values.

Example:

Figure 33. The Frame

Gap Box.

a.Lines from the next scan have a small space gap between the previous scan.

b.Decrease the Frame Gap value by 1.

c.Press the Set Gap button.

d.Repeat the test until alignment is correct.

6.Click on Done when finished.

iNote

Adding (+) numbers moves the scans further apart.

Subtracting (-) moves the scans closer together.