Page 50
Image 50

5.

 

Observe

 

 

the

 

startup

messages

and check

that

the

device

 

driver

IBMIDECD.SYS

 

 

 

 

 

loads.

When

MSCDEX

loads,

observe

the

 

drive

letter

that

 

the

computer assigns

 

 

 

 

to

the

 

 

CD-RW

drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

 

Load

a

 

 

data

CD

 

into

the

CD

tray;

then

wait

until

 

the

busy

indicator

is

not

lit.

7.

 

Attempt

 

 

to

read

 

from

the

CD

by

typingdir x:

where

x

is

the

CD-RW

drive

 

 

 

 

letter

 

assigned

after

the

 

MSCDEX

message.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ÿ

If

 

 

the

 

computer

is

 

able

to

read

the

CD,

a conflict probably exists between the

 

 

 

device

drivers

 

loaded

 

in

the

CONFIG.SYS or AUTOEXEC.BAT files. You

 

 

 

 

 

 

 

 

need

 

to

resolve

this

device

conflict. You might have to set some

 

 

 

 

 

 

 

configuration

parameters

 

for your

installation;

refer

to

 

Appendix

C,

 

 

 

 

 

 

 

 

 

“Customizing device driver configuration settings” on page

2-13

for

more

 

 

 

 

 

 

 

information.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ÿ

If

 

 

you

are

 

unable

to

access

the

CD,

you

might

 

have

a

hardware

problem.

If

 

 

 

 

you

 

are

unable

 

to

read

from

the

 

CD

or

 

a

drive

letter

is not

assigned

by

 

 

 

 

MSCDEX,

go

to

the

 

next

step.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.

 

Turn

off

 

the

computer,

unplug

the

cables

from

the

electrical

outlets

for

your

 

 

 

 

 

computer

 

and

all

attached

 

devices,

and

remove

the

computer

 

cover.

 

 

 

 

 

 

 

9.

Disconnect the IDE and

 

power

cable

for

all

IDE

devices

except

the

CD-RW

 

 

 

 

 

drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.

 

Configure

 

 

the

CD-RW

 

drive

as

a

master

and

connect

it

 

to

 

the

last

IDE

connector

 

 

on

the

 

 

primary

IDE

port.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.

Reinstall

the

computer

cover.

Reconnect

all

devices;

then

plug

the

power

cords

 

 

 

 

into

electrical

outlets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12.

Place the System Diskette

in

the

diskette

drive

and

 

a

data

CD

in

the

CD-RW

 

 

drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13.

 

Restart

 

 

the

computer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14.

 

Attempt

 

to

read

from

the

CD

 

by

typingdir C:.

(The

 

CD-RW

drive

is

drive

C

 

 

because

it

is

the

only

device

connected

to

the

IDE

port.)

 

 

 

 

 

 

 

 

 

Ÿ

If

 

 

the

 

computer

is

 

able

to

read

the

CD,

a

conflict

probably

exists

with one

of

 

 

 

the

 

devices

 

that

was

installed

on

your

computer.

 

You

need

to

resolve

this

 

 

 

 

device

driver

 

conflict.

Check

the

configuration

jumper

settings

for

the

other

 

 

 

 

 

 

devices

or

refer

to

your

device

documentation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ÿ

If

 

 

you

are

 

unable

to

access

the

CD,

you

might

 

have

a

hardware

problem.

If

 

 

 

 

the

 

CD-RW

drive

still

does

not

read

from

the

data

CD,

the CD-RW drive

 

 

 

 

 

 

might

be

defective.

 

Go

to

Appendix

D,

“Help

and

 

service

information” on

 

 

 

 

 

 

 

page

 

2-20.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The

CD

cannot

be

read.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Take

the

following

actions:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

The

CD

might

be

 

dirty;

clean

it

as

described

in

“Handling

and

caring

for

a

CD”

 

 

on

page

 

1-10.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-10

 

 