Electrical input

 

Environment

Sine-wave input (50 to 60

Air temperature:

Hz) is required

 

 

— Expansion unit on: 10°

 

 

 

 

 

• Input voltage:

 

 

to 35° C (50° to 95° F)

Low range:

 

 

Altitude: 0 to 914 m

 

 

(3000 ft)

 

Minimum: 90 V ac

 

 

 

— Expansion unit on: 10°

 

Maximum: 127 V ac

 

 

 

to 32° C (50°

High range

 

 

to 90° F) Altitude: 914 m

 

Minimum: 198 V ac

 

(3000 ft.) to 2133 m (700

 

 

ft)

 

 

 

 

 

 

Maximum: 257 V ac

Humidity: 8% to 80%

— Input kilovolt-amperes

Size (with front panel and

 

(kVA) approximately:

 

Minimum

 

without mounting rails

 

 

Depth: 53.8 cm (21.2 in)

 

 

configuration:

0.06

 

 

kVA

 

• Height: 12.8 cm (5 in)

 

Maximum

 

 

 

• Width: 44.7 cm (17.6 in)

 

 

configuration:

0.45

 

 

 

 

 

 

kVA

 

Weight

 

 

 

 

 

 

 

 

• Standard expansion unit as

 

 

 

 

 

shipped: 22.5 kg (49.5 lbs)

 

 

 

 

• Typical expansion unit fully

 

 

 

 

 

loaded: 36.1 kg (79.4 lbs)

 

 

 

 

 

 

Acoustical noise emissions values

For open bay (no drives installed) and maximum system configurations (14 hard disk drives installed).

Sound power (idling):

5.6 bels (open bay)

5.7 bels (typical)

Sound power (operating):

5.6 bels (open bay)

6.5 bels (typical)

Sound pressure (idling):

44 dBA (open bay)

47 dBA (typical)

Sound pressure (operating):

44 dBA (open bay)

54 dBA (typical)

These levels are measured in controlled acoustical environments according to ISO 7779 and are reported in accordance with ISO 9296. The declared sound power levels indicate an upper limit, below which a large portion of machines operate. Sound pressure levels in your location might exceed the average 1-meter values stated because of room reflections and other nearby noise.

System-management software support

The Netfinity EXP300 provides software alert functions through the system monitor functions provided in the IBM Netfinity Manager, IBM Netfinity Director, and IBM ServeRAID manager software.

The following alerts are supported:

Disk drive disabled

Power supply failure

Cooling failure

IBM Netfinity EXP300 too hot

Vital Product Data for subcomponents

Note: You must have the correct level of management software on your server to enable this functionality.

6IBM Netfinity EXP300 - Type 3531 Hardware Maintenance Manual

Page 14
Image 14
IBM 3531 manual System-management software support