Table 2. Abbreviated list of POST error codes (continued)

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

8603

Pointing-device error.

1. Reseat the pointing device.

 

 

 

 

2.

Replace the following

 

 

 

components one at a time, in

 

 

 

the order shown, restarting the

 

 

 

server each time:

 

 

 

a.

Pointing device

 

 

 

b.

(Trained service technician

 

 

 

 

only) System board

 

 

 

 

 

00012000

Processor machine check error.

1.

(Trained service technician

 

 

 

 

 

only) Reseat the

 

 

 

microprocessor.

 

 

2.

Replace the following

 

 

 

components one at a time, in

 

 

 

the order shown, restarting the

 

 

 

server each time:

 

 

 

a.

(Trained service technician

 

 

 

 

only) Microprocessor

 

 

 

b.

(Trained service technician

 

 

 

 

only) System board

 

 

 

 

00019701

Microprocessor 1 failed the built-in

1.

(Trained service technician

 

self-test (BIST).

 

only) Reseat the

 

 

 

 

 

 

microprocessor.

 

 

2.

Replace the following

 

 

 

components one at a time, in

 

 

 

the order shown, restarting the

 

 

 

server each time:

 

 

 

a.

(Trained service technician

 

 

 

 

only) Microprocessor

 

 

 

b.

(Trained service technician

 

 

 

 

only) System board

 

 

 

 

01298001

No update data for microprocessor

1.

Update the BIOS code again

 

1.

 

(see the Problem

 

 

 

 

 

 

Determination and Service

 

 

 

Guide on the IBM xSeries

 

 

 

Documentation CD).

 

 

2.

(Trained service technician

 

 

 

only) Reseat the

 

 

 

microprocessor.

 

 

3.

(Trained service technician

 

 

 

only) Replace the

 

 

 

microprocessor.

 

 

 

 

 

60xSeries 206m Types 8485 and 8490: Installation Guide

Page 74
Image 74
IBM 8485, 8490 manual Only Replace