Table 2. Abbreviated list of POST error codes (continued)

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

 

175

Service processor flash code

1. Update the Remote Supervisor

 

damaged or not loaded.

 

 

Adapter II firmware (see the

 

Note: In this case, the service

 

 

 

Problem Determination and

 

processor is the optional Remote

 

 

 

Service Guide on the IBM

 

Supervisor Adapter II.

 

 

 

xSeries Documentation CD).

 

 

 

 

 

2.

Replace the Remote

 

 

 

Supervisor Adapter II.

 

 

 

 

 

184

Power-on password damaged.

1.

Run the Configuration/Setup

 

 

 

 

 

Utility program, select Load

 

 

 

Default Settings, and save the

 

 

 

settings.

 

 

2.

Reseat the battery.

 

 

3.

Replace the following

 

 

 

components one at a time, in

 

 

 

the order shown, restarting the

 

 

 

server each time:

 

 

 

a.

Battery

 

 

 

b.

(Trained service technician

 

 

 

 

only) System board

 

 

 

 

 

187

VPD serial number not set.

1. Set the serial number by

 

 

 

 

 

updating the BIOS code level

 

 

 

(see the Problem

 

 

 

Determination and Service

 

 

 

Guide on the IBM xSeries

 

 

 

Documentation CD).

 

 

2.

(Trained service technician

 

 

 

only) Replace the system

 

 

 

board.

 

 

 

189

Three attempts were made to

Restart the server and enter the

 

access the server with an incorrect

administrator password; then, run

 

password.

the Configuration/Setup Utility

 

 

program and change the power-on

 

 

password.

 

 

 

 

 

52xSeries 206m Types 8485 and 8490: Installation Guide

Page 66
Image 66
IBM 8485, 8490 manual Determination and Service