Table 2. Abbreviated list of POST error codes (continued)

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Problem Determination and Service Guide to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Error code

Description

Action

 

 

 

 

 

1600

The service processor is not

1. If the optional Remote

 

functioning.

 

Supervisor Adapter II is

 

Note: Depending on which device

 

installed:

 

is installed, the service processor

 

a.

Update the Remote

 

is the optional Remote Supervisor

 

 

Supervisor Adapter II

 

Adapter II or the mini-BMC.

 

 

 

firmware (see the Problem

 

 

 

 

 

 

Determination and Service

 

 

 

Guide on the IBM xSeries

 

 

 

Documentation CD).

 

 

b.

Replace the Remote

 

 

 

Supervisor Adapter II.

 

 

2. Update the mini-BMC firmware

 

 

(see the Problem

 

 

Determination and Service

 

 

Guide on the IBM xSeries

 

 

Documentation CD).

 

 

3. (Trained service technician

 

 

only) Replace the system

 

 

board.

 

 

 

 

54xSeries 206m Types 8485 and 8490: Installation Guide

Page 68
Image 68
IBM 8485, 8490 manual Update the mini-BMC firmware