OCPRF100 MP Server System Technical Product Specification

Revision 1.0

 

SAFETY AGENCY

 

 

 

MANUFACTURER

 

LOGO

MARKINGS

 

 

 

 

MANUFACTURER NAME

MANUFACTURER MODEL NO. AND REVISION

AUTORANGING INPUT: 50/60HZ

INPUT 100-120V ~ 12A, OUTPUT 650W

+3.3V

 

 

31.0A MAX

-12V

 

 

1.0.A MAX

 

 

+5V

 

 

31.0A MAX

+5VSB

 

 

1.0A MAX

 

 

 

 

+12V

 

 

31.0A MAX

+15VSB

 

 

0.2A MAX

 

 

 

 

 

 

INPUT 200-240V ~ 7A, OUTPUT 750W

 

 

+3.3V

 

 

33.0A MAX

-12V

 

1.0.A MAX

+5V

 

 

33.0A MAX

 

 

 

+5VSB

 

1.0A MAX

+12V

 

 

33.0A MAX

 

 

 

+15VSB

 

0.2A MAX

 

 

 

 

 

 

P/N:

 

 

 

 

 

 

 

 

 

CODE 3 OF 9 BAR CODE

 

 

 

 

 

 

 

 

 

 

 

 

HUMAN READABLE PART NUMBER

S/N

CODE 3 OF 9 BAR CODE

HUMAN READABLE SERIAL NUMBER

DATE CODE :XXXX

COUNTRY OFORIGIN

Figure 5-3: Internal Label

The power supply is marked with the international label to indicate that no user serviceable parts are contained in the power supply. This label is shown in Figure 5-4: Service Label. This label is printed on bright yellow vinyl label stock with black symbols.

Figure 5-4: Service Label

Note:The temperature of the power supply chassis cannot exceed 70° C under all circumstances; otherwise, a UL international HOT SURFACE label must be added. This HOT SURFACE label, if required, will be placed in such a way that when the power supply is extracted from the system, the label will be visible before the operator has a chance to touch the hot surface of the power supply.

57