OCPRF100 MP Server System Technical Product Specification
Revision 1.0
Table
| Single Power Supply Load Condition |
| |
|
|
|
|
Voltage | Minimum Continuous | Maximum Continuous | Peak |
|
|
|
|
+3.3 V | 1.1 A | 36 A |
|
|
|
|
|
+5 V | 0.7 A | 36 A |
|
|
|
|
|
+12 V | 0.7 A | 36 A | 42 A |
|
|
|
|
0 A | 1.0 A |
| |
|
|
|
|
+5 V Standby | 0.05 A | 1.00 A |
|
|
|
|
|
+15 V Standby | 0 A | 200 mA |
|
|
|
|
|
|
|
|
|
The power supply provides remote sense on the +3.3 Vdc, +5 Vdc, and +12 Vdc outputs and their common DC return to provide regulation at those remote points.
5.5.4.3Ripple and NoiseRipple and noise are defined as periodic or random signals over the frequency band of 10 Hz to 30 MHz. The power supply DC output ripple and noise will not exceed the values shown in Table
Table
VOLTAGE | Ripple/Noise | Ripple/Noise |
|
|
|
+3.3 V | 1.5% | 50 mV |
|
|
|
+5 V | 1% | 50 mV |
|
|
|
+12 V | 1% | 120 mV |
|
|
|
1% | 120 mV | |
|
|
|
+5 V Standby | 2% | 100 mV |
|
|
|
+15 V Standby | 5% | 750 mV |
|
|
|
|
|
|
60