Developers Manual March, 2003 7-13
Intel® 80200 Processor based on Intel® XScale Microarchitecture
Configuration
7.2.9 Register 8: TLB Operations
Disabling/enabling the MMU has no effect on the contents of either TLB: valid entries stay valid,
locked items remain locked. All operations defined in Table 7 -13 work regardless of whether the
TLB is enabled or disabled.
This register should be accessed as write-only. Reads from this register, as with an MRC, have an
undefined effect.
Table 7-13. TLB Functions
Function opcode_2 CRm Data Instruction
Invalidate I&D TLB 0b000 0b0111 Ignored MCR p15, 0, Rd, c8, c7, 0
Invalidate I TLB 0b000 0b0101 Ignored MCR p15, 0, Rd, c8, c5, 0
Invalidate I TLB entry 0b001 0b0101 MVA MCR p15, 0, Rd, c8, c5, 1
Invalidate D TLB 0b000 0b0110 Ignored MCR p15, 0, Rd, c8, c6, 0
Invalidate D TLB entry 0b001 0b0110 MVA MCR p15, 0, Rd, c8, c6, 1